Войти:

Roberts Gorden Vantage TF TF-380

Скачали: 3Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

/0# 1"( 1 2 ,-. /0# 3 0& 4 567& % 57 1 8 ,-409 *:" ;<" Description Part Number S-Hook 91907302 Tube/Reflector Hanger 03090100 Total Straight Length (both sides) or Length from U-Tube to U-Tube in a Double "U" Layout Typical Expansion Each Side Minimum “X” Length 0’ - 50’ ±1” (3 cm) 12” (31 cm) 51’ - 60’ ±2” (5 cm) 18” (46 cm) 61’ - 80’ ±3” (8 cm) 24” (61 cm) 81’ - 100’ ±4” (10 cm) 30" (76 cm) 101’ - 120’ ±5” (13 cm) 36" (91 cm) 121’ - 140’ ±6” (15 cm) 42" (107 cm) 141’ - 160’ ±7” (18 c

Roberts Gorden Vantage TF TF-350

Скачали: 1Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

Codes for Gas Burning Appliances. Canada: Refer to CAN/CGA B149.1 and B149.2: • Heaters must not be installed less than 8' Installation Codes for Gas Burning Appliances. (2.4 m) above the floor. Minimum clearances to combustibles must be maintained from vehicles parked below the heater. 4.2 Aircraft Hangars • When installed over hoists, minimum Installation in aircraft hangars must be in clearances to combustibles must be maintained accordance with the following codes: from the upper most point

Roberts Gorden Vantage TF TF-300

Скачали: 11Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

14 Figure 13: Linear Heater Assembly Overview ........................ 15 Figure 14: Linear Heater Layout Overview.............................. 16 Figure 15: Linear Heater Layout Overview (Continued) .......... 17 Figure 16: U-Tube Heater Assembly Overview ......................23 Figure 17: U-Tube Heater Layout Overviews .........................24 Figure 18: U-Tube Heater Layout Overviews (Continued).......25 Figure 19: Reflector Joint Detail..............................................27 Fi

Roberts Gorden Vantage TF TF-250

Скачали: 0Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

SECTION 6: SUGGESTED LAYOUTS SECTION 6: SUGGESTED LAYOUTS The following are suggested layouts for the heater. These layouts are effective in maximizing the heat pattern and overall performance of the heater. All heaters can be common vented or individually vented (See Page 34, Section 9) depending on the building requirements. These are only suggested layouts. The heater can be designed in various configurations provided they are in the guidelines of this manual. When designing a U-Tube or Elbow

Roberts Gorden Vantage TF TF-200

Скачали: 2Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

Coupling Assembly with Lock Reflector End Cap Punch out center section to accommodate tube. Tube and Reflector Hanger Suspend system from these hangers. Flex Gas Line with Shut Off Cock Tube Hot Rolled or Heat Treated Aluminized Tube Supplied in 10' (3 m) lengths. Burner Tube Supplied in 10' (3 m) lengths. Burner tube is always the first tube after the burner. Reflector Support Strap & Wire Form Turbulator Turbulator must be installed in the last standard section of tube. Turbulator is not requi

Roberts Gorden Vantage TF TF-160

Скачали: 0Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

All dimensions are from the surfaces of all tubes, couplings and elbows. 2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect. FIGURE 2: ONE SIDE REFLECTOR (inches) (centimeters) Model A B C D A B C D . . %. TF-120 TF-160 TF-200 TF-250 TF-300 6 6 6 6 6 9 63 9 70 9 77 9 83 9 86 47 54 59 65 69 16 16 16 16 16 23 161 23 178 23 196 23 211 23 219 120 138 150 166 176 TF-350 8 9 88 73 21 23 224 186 TF-380 8 9 88 73 21 23 224

Roberts Gorden Vantage TF TF-120

Скачали: 3Размер: 5 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

11 6.1 TF-380 - 4 Elbow Design (Common Vent) ................. 11 6.2 TF-350 - 4 Elbow Design (Common Vent) ................. 11 6.3 TF-300 - Double "U" Design (Common Vent) ............ 11 6.4 TF-160 - Single Elbow Design (Individual Vents)....... 12 6.5 TF-160 Double "L" Design (Individual Vents).............12 6.6 TF-250 - Combination "L" and "U" Design (Individual Vents) ....................................................... 12 SECTION 7: Heater Installation.................................

Roberts Gorden VANTAGE NP CTHN-80

Скачали: 0Размер: 7 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

The T and Fork layouts have a tee or cross (called the "last tee" or "last cross") where the combustion gases in the system enter the tee or cross with directly opposing flow directions, which creates an added source of pressure drop in the system. This additional source of pressure drop requires some difference in how the allowed manifold length is calculated. In this case, we have to differentiate manifold tube that is located between the radiant pipe and the last tee (or cross) from manifold

Roberts Gorden VANTAGE NP CTHN-60

Скачали: 11Размер: 7 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

Reflectors can be used over the manifold tube but are not required. The system design parameters are such that the manifold sections are not subjected to condensate when the system is fully heated up. It is required that heat-treated aluminized or coated tubing is used for the manifold to increase system life and to handle initial condensation during start-up. Damper couplings may be necessary to balance system vacuum. Design requirements for a CTHN multiburner system are summarized on Page 30,

Roberts Gorden VANTAGE NP CTHN-40

Скачали: 5Размер: 7 mb    Производитель: Roberts Gorden  
Категория: Электрообогреватели

CTHN-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL 22 Step 8.9 Reflector Installation Description Part Number Tube/Reflector Hanger 03090100 Burner Tube 03051XXX Reflector 02750303 NOTE: All radiant tube surfaces must be covered by a reflector, except for a u-tube. Manifold tube may or may not be covered. SECTION 8: UNITARY LINEAR & U-TUBE HEATER INSTALLATION 23 Step 8.9.1 Reflector, U-clip and Reflector Support Installation The pictorial drawings of the heater construction in Section 8





Категории