Charcoal filters will not remove odors if washed and should be replaced periodically—every few months depending on usage. Replacement filters are available from the manufacturer. Please call 800-875-3654. CONNECTING TO THE VENT PIPE: The hood is equipped with a metal damper. Attach the damper to the hood top or back side of the hood with at least two screws. Duct tape the edges to the hood. Be careful to not damage or tape over the damper blade. When connected to the back of the hood (horziontal
Always observe local building codes. Always use a dedicated circuit. The Trade-Wind® hood is supplied with a 5.0 amp variable speed fan control. Wire connections: (See Diagram Below) There are 3 wires on the front panel that require connection. BLACK 120 VAC from electrical panel (usually black) WHITE Neutral from electrical panel (white) GREEN Ground from electrical panel (usually green) CAUTION: The neutral wire (white) must only be connected to the white neutral wire coming in from the electr
Failure to properly install this product may void the warranty. Installer: Please leave these installation instructions with the range hood. Owner: Please keep these installation instructions for local electrical inspector’s use and for future reference. WARNINGS: Must be followed carefully to avoid personal injury IMPORTANT: Must be followed carefully to avoid damage TIPS: Contain helpful information WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING
Page 2 6. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints with high quality duct tape. 7. Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes. 8. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise specified. IMPORTANT: If the Trade-Wind® hood is installed as a liner for a wood hood, proper installati
Never exhaust into a wall, an attic or a concealed area in the building. This can create a potential hazard. · Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting. Item No. 0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 3 CAUTION: · Locate the cooking area for minimum cross drafts—away from doors and windows, when possible. · Ducts must be of adequate size and duct runs should be as short as possibl
0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 1 INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O® Ultra Series Range Hoods Ultra Series Models: UL2824 UL2830 UL2836 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part 3 - Direction of Vent and Securing The Hood Part 4 - Use & Care READ AND SAVE THESE INSTRUCTIONS Before beginning installation, please thoroughly read and become familiar with these instructions. Installation a
BE CAREFUL NOT TO DRILL THROUGH THE UL LABEL OR INTO THE HOOD’S ELECTRICAL COMPONENTS. DETERMINING THE DIRECTION OF VENTING (TOP, REAR AND RECIRCULATE): TOP VENT BACK VENT RECIRCULATION Top Vent: Range hoods are shipped with the motor and blower installed to vent out the top. However, the vent covers in the rear vent opening and recirculation vent opening must be taped on all edges to prevent air leaks and vibration noise. The vent covers are not taped when shipped from the factory because the d