Войти:

Linear XR-4

Скачали: 13Размер: 323 kb    Производитель: Linear  
Категория: Погодные станции

PRODUCT DESCRIPTION Linear’s Xtended Range FM receivers and transmitters are designed for use in various wireless remote control applications. When the Model XR-4 receiver detects a signal from its companion transmitter, it will verify the digital code, activate the correct output channel, and trigger the remote device connected to the receiver. The XR-4 receiver has full supervision capabilities. If the “status” option is selected, the receiver expects hourly status signals from its transmitter

Linear XR-16

Скачали: 22Размер: 575 kb    Производитель: Linear  
Категория: Моечное оборудование

PRODUCT DESCRIPTION Linear’s Xtended Range FM receivers and transmitters are designed for use in various wireless remote control applications. When the Model XR-16 receiver detects a signal from its companion transmitters, it will verify the digital code, activate the correct output channel, and trigger the remote device connected to the receiver. The XR-16 receiver has full supervision capabilities. If the “status” option for a channel is selected, the receiver expects hourly status signals fro

Linear VS-GSWG

Скачали: 0Размер: 3 mb    Производитель: Linear  
Категория: Автоматические ворота

3. Adjust the OPEN limit nut until it is about 1/2” from activating the LSO-2 OPEN limit switch. 4. Adjust the CLOSE limit nut until it is about 1/2” from activating the LSC-2 CLOSE limit switch. Limit Nuts Fine Adjustment After finishing the rough limit nut adjustments, run the operator to set the fine limit adjustment. 1. Turn the power disconnect switch ON. 2. Stand clear of any moving parts and press the OPEN button. 3. After the gate opens, press the CLOSE button. 4. Observe the gate in bot

Linear TSD-90A

Скачали: 4Размер: 120 kb    Производитель: Linear  
Категория: Пожарные сигнализации

The TSD-90A transmitter is compatible with any Linear SX format supervised security receiver. The TSD-90A sounds a local alarm as soon as smoke is detected. Twenty seconds after the local alarm sounds, the TSD-90A’s transmitter will send an alarm signal to the supervised receiver. The alarm signal will be repeated every 20 seconds as long as smoke is still present. A restoral report will be sent when the smoke detection chamber clears. Supervisory status reports are sent from the TSD-90A every h

Linear SWR

Скачали: 7Размер: 1 mb    Производитель: Linear  
Категория: Автоматические ворота

A wireless contact sensor shallfunction under the intended end-use conditions. RECEIVER INSIDE GATE OPERATORGATE EDGE TRANSMITTERSEPARATE PEDESTRIAN GATE REQUIRED7FT. MINIMUM DISTANCE AWAY FROM GATE EDGE MOUNTED ONLEADING OUTSIDE EDGE OF GATE WIRE EDGESSHOWN TO THE CLOSE OBSTRUCTION INPUT ONLY WARNING One or more contact sensors shall be located on theinside and outside leading edge of a swing gate.Additionally, if the bottom edge of a swing gate is greater than six inches (152 mm) above the gro

Linear SWD

Скачали: 0Размер: 1 mb    Производитель: Linear  
Категория: Автоматические ворота

TURN THE OPERATOR POWER DISCONNECT SWITCH OFF BEFORE MAKING ANY ADJUSTMENTS. To increase the torque, turn the adjustment nut clockwise one flat, or 1/6 turn, at a time until desired output is obtained. To reduce the torque, turn the adjustment nut counterclockwise one flat, or 1/6 turn, at a time until desired output is obtained. 3. When finished, tighten the set screw on the torque limiter adjustment nut. Limit Cam Fine Adjustment After finishing the rough limit cam adjustments and torque limit

Linear SWC

Скачали: 0Размер: 1 mb    Производитель: Linear  
Категория: Автоматические ворота

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Before You Begin... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Always Check the Gate’s Action . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Gate Operator Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Approved Obstruction Detection Devices . . . . . . . . . . . . . . . . . . . . .1 Safety Information and Warnings. . . . . . . . . . . . . . . . . . . . . . .

Linear SP1024

Скачали: 6Размер: 789 kb    Производитель: Linear  
Категория: Зарядные устройства

The clamp at the top of the solar panel should fit over the pin on the curved pipe. Secure with the 1/4” nuts (E). 10 Watt, 24 Volt Compatible with all Linear APeX™ enabled DC Slide and Swing Gate Operators. A B C F G H C E D Parts Included: A. Solar Panel B. Lag Screws (4) C. Pipe Clamp (4) D. Curved Pipe E. 1/4” Nuts (4) F. 1/4” x 1/2” Bolt (4) G. Wire Nuts H. Compass Tools Required : • Slotted (flat blade) Screwdriver • 7/16” open end wrench Step 2: Determine the site for installation of the

Linear SLR

Скачали: 1Размер: 950 kb    Производитель: Linear  
Категория: Автоматические ворота

The controller can also be set to prevent the gate from opening if the shadow loop is triggered while the gate is at the close limit position. This prevents a swing gate from opening into a vehicle if it’s parked near the gate on the inside. Low Power Mode This function is only used with DC slide gate Model SLD. The factory default disables the Low Power Mode.When Low Power Mode is enabled, and AC power fails, the controller will assume Low Power Mode after 60 seconds of gate inactivity. Low pow

Linear SLD

Скачали: 0Размер: 950 kb    Производитель: Linear  
Категория: Автоматические ворота

DC AC ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) DC + RESET RESET BUTTON FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. COMMON B COMM LINK FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS. A COMMON CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES SINGLE BUTTON INPUT BETWEEN OPEN-CLOSE OR OPEN-STOP-CLOSE DEPENDING ON PROGRAMMING. COMMON SINGLE FIRE BOX INPUT CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPART





Категории