Z2149A Rev. 10.11.06 4 5 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #2 – Beer Pump Form No. Z2149A Rev. 10.11.06 6 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #3 – Cleaning Diagram Form No. Z2149A Rev. 10.11.06 Cleaning Instructions General Information ¦ The cleaning of beer lines with the new integral flow reversal

Perlick 66134-2

Скачали: 8Размер: 2 mb    Производитель: Perlick  
Категория: Диспенсеры

¦ Cut a piece of CO2 tubing (red 9/16” vinyl tubing) and push one end onto barbed CO2 outlet to Keg Couplers (See diagram on page3). Position clamp over joint and tighten. Push the other end over the barbed gas inlet on the Perlick Smart Coupler. Position clamp over joint and tighten. Important Notes . CAUTION: If using CO2 as a pressure supply for pumps, pump exhaust must be vented to a well ventilated area to avoid possible asphyxiation. . Never use a single keg to supply more than one beer pu

Perlick 66134-3

Скачали: 0Размер: 2 mb    Производитель: Perlick  
Категория: Диспенсеры

Adjust the Secondary Air/ CO2 regulator located on the beer pump panel to a minimum operating pressure of 10 psig. Smart Coupler Probe Valve Lever Positions ¦ Connect the coupler to a regulated water supply with pressure less than 30 psig. Note: Pump damage may occur with pressure higher than 30 psig. ¦ Open the water supply. Then open probe valve on Perlick Smart coupler to the 45° position. See figure 2. The beer pump will slowly pump up the beer line in the trunk housing to set psig. Note: If

Perlick 66134-4

Скачали: 1Размер: 2 mb    Производитель: Perlick  
Категория: Диспенсеры

Beer pump panels should not be installed with a height of greater than 5 feet from the cooler floor. A height greater than 5 feet will potentially cause flow issues and require system re-balancing. (Note: Make sure panel is level and pumps are in the vertical position). ¦ Drill 9/64” pilot holes in cooler wall. Use fasteners provided in installation kit to mount the beer pump panel to the cooler wall. ¦ Push CO2 supply line over barbed CO2 supply inlet. (See diagram on page 3). Position clamp ov

Perlick BC24 Series

Скачали: 2Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, call Perlick at 1-800-777-7267 or your dealer who can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval. We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction. IMPORTANT WARRANTY INFORMATION A Warranty card is enclosed that mus

Perlick BC36 Series

Скачали: 8Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

INSTALLATION AND OPERATION INSTRUCTIONS FLAT TOP BOTTLE COOLER Table of Contents Cabinet Specifications ..........................................2 Installing Uncrating and Inspection ................................3 Plumbing .........................................................3 Electrical..........................................................3 Adjusting Partitions .........................................3 Installing Casters and Legs.............................3 Placing the Cabinet...

Perlick BC48 Series

Скачали: 3Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 2 Rev. 4.15.06 Preparing the Cabinet – Flat Top Bottle Coolers Uncrating and Inspection Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit. Plumbing No plumbing connections are required. Condensate from the cooling coil automatically ev

Perlick BC60 Series

Скачали: 2Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

BEAD SILICON SEALER (RTV) FLOOR CABINET Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 3 Rev. 4.15.06 How To Operate – Flat Top Bottle Coolers Temperature Control An adjustable temperature control is located inside the Bottle Cooler on the evaporator fan panel assembly. It is factory set at “Normal” approximately 38° F. Make adjustments as shown to attain the desired temperature. NOTE: A temperature se

Perlick BC72 Series

Скачали: 12Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

STAINLESS STEEL ENEMY ¦ Steel wool or steel scouring pads ¦ Cherry/Orange/Olive juice ¦ Chlorine Bleach ¦ Sharp Objects Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 4 Rev. 4.15.06 Wiring Diagram – Flat Top Bottle Coolers GREEN PLUG-IN-CORD BLACK WHITE WHITE EVAP. FAN EVAP. FAN 2ND FAN ON 4’ THRU 8’ MODELS TEMPERATURE CONTROL RED BLACK TO CONDENSING UNIT INSIDE OF CONDENSING UNIT HOUSING INSIDE OF CAB

Perlick BC96 Series

Скачали: 2Размер: 337 kb    Производитель: Perlick  
Категория: Диспенсеры

bend) 63553-1 63553-1 63553-1 63553-1 63553-1 63553-1 Evaporator tube (41.8” U. bend) 63554-1 63554-1 63554-1 63554-1 63554-1 63554-1 Cap tube/suction line heat exchanger with dryer 65072 65072 65073 65075 65075 65075 Mullion assembly — — 64823R 64823R 64823R (2) 64823R Light kit (accessory only) 63536 63536 63536 63536 63536 63536 Refrigerant charge (oz. R134a) 6.0 8.5 9.0 9.0 9.0 9.0 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications withou