|
Фрагмент инструкции
0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 1 INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O® Ultra Series Range Hoods Ultra Series Models: UL2824 UL2830 UL2836 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part 3 - Direction of Vent and Securing The Hood Part 4 - Use & Care READ AND SAVE THESE INSTRUCTIONS Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and service must be completed by a qualified installer. Failure to properly install this product may void the warranty. Installer: Please leave these installation instructions with the range hood. Owner: Please keep these installation instructions for local electrical inspector’s use and for future reference. WARNINGS: Must be followed carefully to avoid personal injury IMPORTANT: Must be followed carefully to avoid damage TIPS: Contain helpful information WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING: · Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. · Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. · Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Item No. 0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 2 WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: · Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) or fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. · When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. · Duct fans must always be vented to the outdoors. WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: · Never leave surface units unattended at high settings. Boil-overs may cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. · Always turn hood ON when cooking at high heat or when cooking flaming foods. · Clean filters and ventilating fans frequently. Grease should not be allowed to accumulate on filter or fan. · Use proper pan size. Always use cookware appropriate for the size of the surface element. WARNING! TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: · SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. · NEVER PICK UP A FLAMING PAN—you may be burned. · DO NOT USE WATER, including wet dishcloths or towels—a violent steam explosion will result. · Use an extinguisher ONLY if: - You know you have a Class ABC extinguisher, and you already know how to operate it. - The fire is small and contained in the area where it started. - The fire department is being called. - You can fight the fire with your back to an exit. *Based on “Kitchen Fire Safety Tips” published by the NFPA. PART 1 Planning the Installation CAUTION: · For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. · To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never exhaust into a wall, an attic or a concealed area in the building. This can create a potential hazard. · Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting. Item No. 0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 3 CAUTION: · Locate the cooking area for minimum cross drafts—away from doors and windows, when possible. · Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep turning radius as large and as smooth as possible. · The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints with high quality duct tape. · Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes. 1. A qualified person must complete the installation of this appliance. 2. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearance...
Эта инструкция также подходит к моделям:Вентиляторы - UL2824 (290.25 kb)
Вентиляторы - UL2836 (290.25 kb)