Войти:

Louisville Tin and Stove 000 BTU

Скачали: 0Размер: 218 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

Cozy is a perfect answer for either new construction or remodeling heating applications. Single or Dual Wall Models Available WARM AIR RADIANT HEAT RETURN AIR WALL WARM AIR RADIANT HEAT RETURN AIR WALL COZY VALUE FEATURES ¦ Neutral Bone Baked Enamel Finish - resists fading and cleans easily with a damp cloth. ¦ Resettable Blocked Flue Safety Device automatically shuts the unit off in the event of flue blockage or incorrect vent installation. ¦ “Unibody” Grill Construction - of heavy gauge steel

Louisville Tin and Stove 000 TO 50

Скачали: 1Размер: 218 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

. . makes installation a snap! ROUGH-IN DIMENSIONS REAR REGISTER OUTLET LOCATION 141/4" MIN. 141/2" MAX. 653/4" 453/4" 125/8" 81/4" PLASTER PLATE REAR REGISTER FRAME OPENING FOR REAR REGISTER MODEL OPENING 7/8" FROM EACH STUD NAIL TO STUDS PLASTER STUD PLASTER4" 4" Model Type Type BTU/Hr. Vent Gas Finished Shipping Rear Register Kit Fan Kit Number Control Gas Input Size Inlet Dimensions Weight Model Weight Model Weight W251 Bulb Nat. 25,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs.

Louisville Tin and Stove 25

Скачали: 4Размер: 218 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

Engineered for years of efficient, trouble free service Featuring 20 gauge aluminized combustion chambers, warranted for 10 years. Single Wall Furnace models may be equipped with a Rear Register Kit and Grille (40542) allowing warm air to circulate into the adjoining room. Adjustable vent controls air flow. Resettable Blocked Flue Safety Device automatically shuts the unit off in the event of flue blockage or incorrect vent installation. Continuous Seam-Welded Combustion Chamber constructed of h

Louisville Tin and Stove 5000 BTU

Скачали: 11Размер: 196 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

Seal Direct Spark Ignition Module Self-Diagnosing Inside Finish Mounting Template, 24 Volt Wall T-Stat Kit, Power Cord and Flex Connector with Ball Valve Vent Weather Seal Kit with 2" I.D. Seal Vent Riser Kit SPECIFICATIONS Model No. Input BTU/Hr. Watts Type Gas Type Control AFUE Width Depth Height Gas Conn. Voltage Minimum Center of Vent to Floor Wall Opening Wall Max Thickness Wall Min Thickness Ship Weight BBT53 5,000 1,465 Nat. 24 Volt 73.0% 48” 5-3/8” 9-3/8” 3/8” 115V 7-7/16” 2-1/2”

Louisville Tin and Stove 78111

Скачали: 11Размер: 428 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

23 95271 3.80 $ 78168 $ 3.80 Fan Motor 24 72108 82.30 $ 78111 $ 95.50 Fan Blade 25 78101 26.90 $ 78101 $ 26.90 Rubber Grommet 26 78010 3.40 $ 78010 $ 3.40 Limit Switch 27 78065 6.60 $ 78065 $ 6.60 Fan Switch 60T12-F120 28 78067 6.80 $ 78067 $ 6.80 Speed Switch F160-30 29 N/A N/A 78066 $ 9.90 Auxiliary Limit Switch 60TG15 350 Deg., Lower 30 78086 10.40 $ 78086 $ 10.40 Thermostat 31 78355 22.30 $ 78355 $ 22.30 Transformer 32 78069 26.20 $ 78069 $ 26.20 Flue Pipe Adapter 32b 40061 2.20 $ 40061 $ 2.

Louisville Tin and Stove 9000 BTU

Скачали: 16Размер: 196 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

They are eminently reliable and safe. Cozy Baseboard Heaters are approved for use in mobile home applications. Always consult with your local building code officials. Manufacturers of Heating Equipment Since 1888 FEATURES INCLUDE: ■ Two models 5,000 BTU (4 Ft.) and 9,000 BTU (6 Ft.) to choose from. ■ 24 Volt thermostat (115 volt required). ■ Wall thermostat and power cord (9 Ft.) included. ■ Transistorized control module. ■ Tubular, aluminized combustion chamber warranted for 10 years -

Louisville Tin and Stove 90N30A

Скачали: 1Размер: 210 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

pressure. Based on a pressure drop of 0.5 inches water column. **Copper tubing must comply with limitations of NATIONAL FUEL GAS CODE reference 2.6.3 metallic tubing. ***Steel pipe should be of at least standard weight (Schedule 40). Support the piping or tubing at regular intervals with metal pipe strapping. See chart below. Nominal Steel Spacing of Pipe Size Supports 1/2” 6’ 3/4” or 1” 8’ Nominal size of Spacing of tubing O.D. Supports 1/2” 4’ 5/8” or 3/4” 6’ Where local conditions include ear

Louisville Tin and Stove 90N50A

Скачали: 0Размер: 210 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

SETTING THE FLOOR FURNACE Lay aside the grill and package containing the thermostat, wires, etc., grasp two opposite sides of the outer casing and lower the floor furnace gently through the opening. Support the furnace evenly by the flange at the top of the outer casing. Trim back carpet, padding, and other types of floor covering so that the entire flange rests directly on the floor. If not evenly supported on all four sides, stresses may be created that cause excessive expansion and contractio

Louisville Tin and Stove 90N65A

Скачали: 47Размер: 210 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

Not enough heat 1. Appliance undersized 2. Thermostat set too low. 3. Incorrect supply pressure. 1. This is especially true when a dwelling or room is enlarged. Have the heat loss calculated and compare to the appliance output (70% of input). Your gas company or installer can supply you with this information. If appliance is undersized, replace with correct size unit. 2. Setting of thermostat. See “Lighting and Shutting Down Instructions”. 3. Check supply pressure as outlined above. Too much hea

Louisville Tin and Stove 90N75A

Скачали: 0Размер: 210 kb    Производитель: Louisville Tin and Stove  
Категория: Электрообогреватели

WARNING: Do not attempt to change pressure settings without proper training and instruments. To do so may cause your floor furnace to malfunction resulting in property damage, bodily injury, or death. The following information is provided for use by a trained service technician with measuring instruments. Minimum Inlet Pressure, Natural Gas……………………………………………………. 4.5 Inches Water Column Minimum Inlet Pressure, Liquefied Petroleum (L.P.) Gas……………………………….. 11.0 Inches Water Column Maximum Inlet Pres





Категории