Aico Carbon Monoxide Alarm Ei 220EN

Скачали: 0Размер: 138 kb    Производитель: Aico  
Категория: Пожарные сигнализации

The Blue wire (terminal 4) must be connected to the house coloured blue or to a house terminal marked “N”. The alarm does not need to be earthed, however for convenience a spare terminal (no. 5) is provided to hold an earth wire if present. 7. Turn on the mains power to the CO Alarm circuit. Figure 5 - Surface Wiring Figure 6 - Recessed Wiring Conduit Not Suitable Locations for Surface Wiring 17 Ei220EN (Only) 1. Slide the cover off as shown in Figure 7 to expose the mounting screw holes. 2. Cut

Aico Carbon Monoxide Alarm Ei 225EN

Скачали: 0Размер: 138 kb    Производитель: Aico  
Категория: Пожарные сигнализации

The leaflet should be regarded as part of the product. If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to any subsequent user. INSTRUCTIONS CONTENTS Page READ THIS FIRST 3 WHAT TO DO WHEN THE CO ALARM SOUNDS 4 CARBON MONOXIDE - THE SILENT KILLER! 5 WHERE TO PLACE CARBON MONOXIDE ALARMS 11 INSTALLING YOUR CARBON MONOXIDE ALARMS 15 TESTING YOUR CARBON MONOXIDE ALARMS 19 MAINTAINING CARBON MONOXIDE ALARMS 20 LIMITATIONS OF CARBON MONOXID

Aico Carbon Monoxide Alarms 260 Series

Скачали: 0Размер: 694 kb    Производитель: Aico  
Категория: Пожарные сигнализации

With over 30 years experience in the fire and gas detection industry our proven high quality design, manufacturing and testing processes have established us as Europe's leading manufacturer of residential smoke, heat and carbon monoxide detection products. We provide high performance products tailored to the needs of specifiers, contractors and house-owners. Quality in our life saving products is never compromised. We have a record of industry firsts including the first BSI Kitemarked range, the

Aico Ei Ei161RC

Скачали: 0Размер: 499 kb    Производитель: Aico  
Категория: Пожарные сигнализации

2 Some Fire Authorities recommend that both Ionisation and Optical Smoke Alarms should be fitted for the fastest response to all types of fires. 3 Some Fire authorities (concerned with the slow response of Heat Alarms) advise that Smoke Alarms should be fitted. This is acceptable according to BS 5839-6 provided there are clearly not going to be problems with nuisance alarms. Fit Heat Alarms only if nuisance alarms are very likely and it is acceptable that a warning will only be given by the Heat

Aico Ei Ei164RC

Скачали: 0Размер: 499 kb    Производитель: Aico  
Категория: Пожарные сигнализации

REMOVE ALARM LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM. THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW. INSERT SCREWDRIVER E PUSH AWO WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER HALF OF THE ALARM AWAY FROM THE SCREWDRIVER, IN THE DIRECTION OF THE ARROW ON THE COVER LOCATE REMOVAL SLOT APPROX. 1cm INTO THE CENTRE OF THE REMOVAL SLOT INSERT A FLAT-BLADED SCREWDRIVER HORIZONTALLY TO REMOVSCREWDRIV& PUSH COVEER INTOSLR AY 3 B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 3 2. HOW MANY A

Aico Ei Ei166RC

Скачали: 2Размер: 499 kb    Производитель: Aico  
Категория: Пожарные сигнализации

(Excessive dust and debris from building work can contaminate the smoke chamber or heat sensor and cause problems, it will also invalidate the guarantee). If it must be installed, first cover it completely, particularly around the edges, with a dust cover (eg. with the elasticated cover supplied or a plastic bag), until all cleaning is finished. The Alarm must not be connected when the house wiring insulation is being checked with high voltages. i.e. Do not use a high voltage insulation tester o

Aico Ei Ei168RC

Скачали: 0Размер: 499 kb    Производитель: Aico  
Категория: Пожарные сигнализации

Ensure the alarm operates correctly - see “TESTING & MAINTAINING YOUR ALARM” section on page 4 of the USER INSTRUCTIONS. 13 B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 13 4.2 Interconnecting Alarms Note: A maximum of twelve Ei141/144/146/161RC /164RC/166RC Smoke or Heat Alarms may be interconnected along with an Ei128R pattress with relay (see “ACCESSORIES” section on page 15). If you wish to connect more than twelve alarms contact your local distributor (see page 16 for details). Systems u

Aico Ei169RF

Скачали: 1Размер: 106 kb    Производитель: Aico  
Категория: Пожарные сигнализации

Supplied with locking plug and 2m of cable. Vibration Pad Socket: Locking socket (JST type VHR-2N) provided for vibration pad. Output 12V/200mA is pulsed in alarm for greater effect. Wiring is monitored - if vibration pad is not connected or if it is open circuit the strobe will flash. • Green mains indicator illuminates to show mains power is present • Red battery indicator flashes when mains power is off to show that the unit is running on battery only power. The red indicator goes off when th

Aico Ei176RF

Скачали: 2Размер: 106 kb    Производитель: Aico  
Категория: Пожарные сигнализации

Aico's range of alarms for the deaf and hearing impaired are the only units currently manufactured by an experienced European smoke alarm supplier. They are also available with RadioLINK wire free radio signal technology, for ease of installation. System Features & Benefits • Control panel with rechargeable battery back-up, mains power supply lead and 13 amp Plug • High intensity integral strobe light • Auxiliary socket for connection of additional optional strobe lights • Vibrating pad for plac

Aico Ei261DENRC

Скачали: 0Размер: 272 kb    Производитель: Aico  
Категория: Пожарные сигнализации

12 B16132-R0-7/11/07 11:52 AM Page 13 1 to 3 m 1 to 3 m DEAD AIR DON'T LOCATE HERE CO Alarm Figure 1. Location in room with a fuel burning appliance - 1 to 3m from appliance - Ceiling 300mm (min) from walls - Wall 150mm vertically down from ceiling 300mm 150mm 13 B16132-R0-7/11/07 11:52 AM Page 14 300mm CO Alarm Figure 2. Location in rooms with sloped ceilings - 300mm from apex of ceiling - High side of the room CO Alarm approx 1 to 2m Figure 3. Location in bedroom & rooms remote from the applia