Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  

Amerec AK7

Скачали: 0Размер: 203 kb    Производитель: Amerec  
Категория: Электрогенераторы

or Generator is faulty. 1. Replace control -call AMEREC's Service Department. 2. Replace PCA -call AMEREC's Service Department. Sudden increases in rate water sputters out of steam head. Foaming contaminants in the water supply. 1. Flush tank 3 times. See Section 4. 4209-24 12/09/02 4209-24 12-09-02 AK Series w/K60 Control Owners Manual page 4 1 28 12 4 43 29 15 24 23 2 16 7 8 22 19 5 18 17 20 14 6 13 3 39 33 44 21 34 9 36 35 11 P.O. Box 2258, Woodinville WA 98072 425-951-1120 Fax: 425-951-1130

Amerec PKLE 182

Скачали: 5Размер: 175 kb    Производитель: Amerec  
Категория: Плиты

The floor protection in front of the stove must extend at least to 100mm beyond both side of the oven mouth and to 400mm In front of jt 3 INSTALLING THE STOVE Figi As in all our stoves, there Is an escape hole for the smoke flue on top of the stove as well as behind it. You can close the unnecessary hole using the |r^ closing trap supplied. Included with the delivery, you will also receive a 2,00mm connecting pipe for connecting the stove to the smoke flue through the back hole. When connect

Amerec PKLE 2024

Скачали: 6Размер: 175 kb    Производитель: Amerec  
Категория: Плиты

You can close the unnecessary hole using the |r^ closing trap supplied. Included with the delivery, you will also receive a 2,00mm connecting pipe for connecting the stove to the smoke flue through the back hole. When connecting the stove to the smoke flue through the hole on top of the stove, we recommend you use our connecting pipes which are available as accessories- When doing this, do not forget to dose the smoke hole behind the stove using the closing trap supplied. (Figure 8) Do not inst

Amerec Steambath Generator 3K10

Скачали: 0Размер: 121 kb    Производитель: Amerec  
Категория: Электрогенераторы

3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA & STEAM 17683 128th Place NE, Building C Woodlnvflie, Washington 98072, USA 425*951-1120 Fax: 425-951-1130 4209-38 9-15-04

Amerec Steambath Generator AK10

Скачали: 2Размер: 121 kb    Производитель: Amerec  
Категория: Электрогенераторы

3 Verily that the Generator s drain vafve is closed. 4 If the above 4 steps do not disclose the problem turn off the Generator s circuit breaker Call AMERECs Servicc Department Control 'OFP (Control liolil oil) Unit still makes steam Control circuit is laolty or Generator is faulty 1 Turn off circuit breaker 2 Call AMEREC s Service Department Water runs out steam head Generator is faulty 1 Turn of 1 circuit breaker 2 Turn elf water. 3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA

Amerec W/K60

Скачали: 0Размер: 203 kb    Производитель: Amerec  
Категория: Электрогенераторы

1. Check that the sensor cable is connected to J4 on the PCA printed circuit assembly. 2. Check the cable connection to the temperature sensor. 3. Replace sensor and/or cable -call AMEREC's Service Department. Control "ON". K60 Control displays "E002". Temperature sensor. or cable shorted. 1. Check sensor cable for damage from nail/staple puncture. 2. Check sensor cable ends for frayed/exposed wire strands. 3. Replace sensor and/or cable -call AMEREC's Service Department. Control "ON". K60 Contr

Amerec Steambath Generator AK4

Скачали: 1Размер: 121 kb    Производитель: Amerec  
Категория: Электрогенераторы

3 Verily that the Generator s drain vafve is closed. 4 If the above 4 steps do not disclose the problem turn off the Generator s circuit breaker Call AMERECs Servicc Department Control 'OFP (Control liolil oil) Unit still makes steam Control circuit is laolty or Generator is faulty 1 Turn off circuit breaker 2 Call AMEREC s Service Department Water runs out steam head Generator is faulty 1 Turn of 1 circuit breaker 2 Turn elf water. 3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA

Amerec Steambath Generator AK8.5

Скачали: 0Размер: 121 kb    Производитель: Amerec  
Категория: Электрогенераторы

3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA & STEAM 17683 128th Place NE, Building C Woodlnvflie, Washington 98072, USA 425*951-1120 Fax: 425-951-1130 4209-38 9-15-04

Amerec PKLE 241

Скачали: 28Размер: 175 kb    Производитель: Amerec  
Категория: Плиты

This kind of single light protection can be constructed either by using a minimum 3 inches thick incombustible cement plate reinforced with fiber, or by fastening an at least 20 gauge sheet metal plate densely enough to the wall. A minimum 1-1/4" space must be left between the protective plate and the wooden surface to be protedted. This can be done by using spacers as intermediate supports (Figure 2) I7ÏÏÏ1 3. The safety distance mentioned on item 1 can be further decreased to minimum 5 inche

Amerec Steambath Generator AK5

Скачали: 1Размер: 121 kb    Производитель: Amerec  
Категория: Электрогенераторы

3 Verily that the Generator s drain vafve is closed. 4 If the above 4 steps do not disclose the problem turn off the Generator s circuit breaker Call AMERECs Servicc Department Control 'OFP (Control liolil oil) Unit still makes steam Control circuit is laolty or Generator is faulty 1 Turn off circuit breaker 2 Call AMEREC s Service Department Water runs out steam head Generator is faulty 1 Turn of 1 circuit breaker 2 Turn elf water. 3. Call AMEREC’s Service Department. /fAMEHEC ////// SAUNA