Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  

Burnham Independence IN10

Скачали: 0Размер: 8 mb    Производитель: Burnham  
Категория: Водонагреватели

Boiler™ Company, Inc. of Lancaster, Pennsylvania issues limited warranties subject to the terms and conditions stated below. These limited warranties apply to residential cast iron boilers labeled Independence®, Independence® PV, V8H™ and MegaSteam™ Series, these warranties are issued only to the original homeowner at the original place of installation. FIRST YEAR - LIMITED WARRANTY FOR RESIDENTIAL CAST IRON STEAM BOILERS U.S. Boiler Company, Inc. warrants its residential cast iron steam boilers

Burnham HF SERIES

Скачали: 0Размер: 676 kb    Производитель: Burnham  
Категория: Водонагреватели

There may be many possible causes of leaks in oil lines such as: 20 i. Fitting leaks due to misflared tubing or damaged fitting. ii. Fuel line leak due to crushed or bent tubing. iii. Filter connection leaks. iv. Tank connection leaks. The following actions can eliminate air leaks: i. Bleed pump as detailed in System Start-Up Section of this manual. ii. Replace flare fittings. iii. Replace oil supply line. iv. Repair oil filter leaks v. Replace or repair tank fittings. e. GASKET LEAKS— If 11.5%

Burnham E4

Скачали: 4Размер: 353 kb    Производитель: Burnham  
Категория: Водонагреватели

rebmuNledoMrelioBrebmuNlaireSrelioBetaDnoitallatsnI_____-__4E_______6 Heating Contractor Phone Number Address 8143606R7-2/06 Price - $3.00 IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION OF BOILER. POST INSTRUCTIONS NEAR BOILER FOR REFERENCE BY OWNER AND SERVICE TECHNICIAN. MAINTAIN INSTRUCTIONS IN LEGIBLE CONDITION. NOTE: — The equipment shall be installed in accordance with those installation regulations in force in the area where the installation is to be

Burnham Hydronics C4

Скачали: 6Размер: 743 kb    Производитель: Burnham  
Категория: Водонагреватели

They are impervious to petroleum-based chemicals, which can deteriorate gaskets used in some competitors’ boilers. Ease of Maintenance and Installation The C3 & C4 Series Boilers are designed for quick, inexpensive servicing. Jacket design allows entry from both the top and side to allow complete access for cleaning. Burner swing door provides easy access to the combustion chamber for fast servicing. Packaged and ready to install with optional tankless coil for domestic hot water. Circulat

Burnham AL-26A

Скачали: 44Размер: 477 kb    Производитель: Burnham  
Категория: Водонагреватели

Normally open contacts open, stopping boiler operation. Domestic hot water priority only: normally closed contacts close, returning boiler control to space heating. D. b. Adjusting to a higher temperature may not immediately affect water temperature. If a heat- up cycle begins, go to step 3. If a heat-up cycle does not begin, draw sufficient water or allow the water heater to sit until a heat-up cycle is initiated. Repeat step 3. To Shut-off Water Heater C. Water Temperature Adjustment 1. The aq

Burnham FREEDOM 101008-01R1-2/07

Скачали: 1Размер: 2 mb    Производитель: Burnham  
Категория: Вентиляторы

For assistance or additional information, consult a qualified installer, service agency or the gas supplier. This boiler requires a special venting system. Read these instructions carefully before installing. 101008-01R1-2/07 Table of Contents I. Product Description ............................................................................ 2 II. Specifi cations ..................................................................................... 2 III. Before Installing .......................

Burnham Condensing Stainless Steel

Скачали: 27Размер: 594 kb    Производитель: Burnham  
Категория: Водонагреватели

Registration is required. 95% HIGH EFFICIENCY • 95%AFUE–HighEfficiency• SevenSizes:80–500MBHforResidential&CommercialApplications• StainlessSteelHeatExchangerforusewithNaturalorPropaneGas(up to 10,200 ft.) • MultipleVentingOptions• CPVC/PVC venting (standard) • Polypropylene concentric (optional) • Stainless steel 2-pipe (optional) • FullyModulatingBoilerOperatingControls(5-to-1 turndown and includes outdoor reset) • Modern,appliance-likedesignwithgas,water,&electricconnectionsonleftside• Polypr

Burnham BH

Скачали: 2Размер: 1 mb    Производитель: Burnham  
Категория: Вентиляторы

When seeking information on heater, provide Model Number and Serial Number as shown on Rating Label located on top of the heater. Model Number Serial Number Installation Date Heating Contractor Phone Number Address 8144A001R4-2/07 TABLE OF CONTENTS I. PRECAUTIONS - IMPORTANT INFORMATION.................................................3 II. GENERAL INFORMATION A. Installation Limitations..............................................................................................4 B. Ins

Burnham LEDV-3

Скачали: 3Размер: 22 kb    Производитель: Burnham  
Категория: Водонагреватели

for both firing rates. 5. As an ENERGY STAR partner, Burnham has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Burnham MST396

Скачали: 1Размер: 6 mb    Производитель: Burnham  
Категория: Водонагреватели

P. AqUASTAT CONTROLLER INSTALLATION (BOILERS WITH TANKLESS HEATER ONLY). 1. On boilers with tankless heater, install the L4006A aquastat controller well (found in Part Carton) into .” NPT tapping in tankless heater plate. 2. Remove the L4006A aquastat controller with factory attached harness from Control Carton. 3. Slip the bulb of the aquastat controller into the well and secure the controller in place with the set screw. WARNING Aquastat bulb must be fully inserted into the well. 4. Feed the L