No such installation, service or maintenance should be undertaken until such technician has thoroughly read this Instruction Manual. Likewise, the owner/ manager should not proceed to operate the dispenser until the installer has properly instructed them on its operation. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the dispenser. Should the reader have any questions or concerns which have not been satisfactori
A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line. • Condenser return outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser return line. • Shut-off valves and drain valves should be installed at both the condenser water supply inlet and condenser return outlet. • The water supply to the condenser should not drop below 4 GPM. • The pressure differential between the condenser water supply inlet and condenser return outlet must be no
Refrigeration Circuit Model: C-100BAE-AD, C-100BAE-ADDS Index No. Description Material or Model Number Part Number Required Number T-0 T-0 (D) U-0 U-1 U-2 1 Compressor QA51K13GAU6 455942-01 1 1 1 1 1a Rubber Grommet 438844-01 4 4 4 4 1b Bolt M6 448834-01 4 4 4 4 2 PTC Relay 456252-01 1 1 1 1 3 Motor Protector 456254-01 1 1 1 1 4 Protector Cover 456255-01 1 1 1 1 5 Clamp 438846-01 1 1 1 1 6 Clip 438847-01 1 1 1 1
Open coil. . Replace. start (compressor). Relay . Open contacts. . Replace. b) Control Board . Defective. . See "II.D.4. Control Board Check Procedure." c) Starter (Start Relay) . Bad contacts. . Check for continuity and replace. . Coil winding open. . Replace. 3. Loose connections. 3. Tighten. d) Start Capacitor or Run . Defective. . Replace. Capacitor e) Compressor . Power supply not . Refer to nameplate and within specifications. correct. . Wiring to compressor. . Check for loose or open conn
°F (°C) 70 80 90 100 *23 (-5) 23 (-5) 23 (-5) 23 (-5) 26 (-4) 26 (-4) 26 (-4) *26 (-4) 28 (-3) 28 (-3) 28 (-3) *28 (-3) HEAD PRESSURE PSIG (kg/cm2G) 70 80 90 100 *230 (16.2) 230 (16.2) 230 (16.2) 264 (18.5) 264 (18.5) 264 (18.5) 297 (20.9) *297 (20.9) 297 (20.9) 335 (23.5) 335 (23.5) *335 (23.5) SUCTION PRESSURE PSIG (kg/cm2G) 70 80 90 100 *33 (2.3) 33 (2.3) 33 (2.3) 35 (2.5) 35 (2.5) 35 (2.5) 37 (2.6) *37 (2.6) 37 (2.6) 43 (3.0) 43 (3.0) *43 (3.0) TOTAL HEAT OF REJECTION 6300 BTU/h (AT 90°F /WT
Note: If there is excess scale on the extruding head, fill the reservoir as described above, then use a clamp on the reservoir hose between the reservoir and evaporator assembly to block flow. Remove the thumbscrews securing the spout, then remove the spout. Pour additional cleaning solution over the extruding head until the evaporator assembly is completely full. Fig. 10 Fig. 11 Slope Scoop Holder Hinge (A) Hinge (B) Hinge Stop Pin Top Panel Spout Extruding Head Reservoir Cover Reservoir Reserv
20, 2005 HOSHIZAKI SELF-CONTAINED CUBER MODEL AM-100BAE AM-150BAF AM-150BWF INSTRUCTION MANUAL FOREWORD Only qualified service technicians should attempt to install, service or maintain this icemaker. No such installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/ manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation. IMPORTANT HOSHIZAKI provides t
. . . i CONTENTS PAGE I. SPECIFICATIONS---------------------------------------------------------------------------------------1 1. SPECIFICATIONS-----------------------------------------------------------------------------------1 [a] KMD-410MAH (air-cooled) ---------------------------------------------------------------------1 [b] KMD-410MWH (water-cooled) ----------------------------------------------------------------2 II. GENERAL INFORMATION------------------------------------------
16, 2004 HA CONTENTS MATERIAL ABBREVIATIONS................................................................................................ 4 A. ICE DISPENSER ASSEMBLY .......................................................................................... 5 B. FRAME ASSEMBLY ......................................................................................................... 7 C. ICE MAKING UNIT ASSEMBLY .....................................................................................
Counter Reset Button (not used in this application) Portion Control Timer "WTR" LED (X5 Relay) Dispensing Water Valve "FLUSH" LED (X6 Relay) Drain Valve 4V Supply Out Microprocessor (board revision level indicated by last digits on label) "ICE" LED (X4 Relay) Shutter Solenoid, Dispensing Auger Motor 4V In 5V In Drain Valve 4V In 4V Out Dispensing Dispensing Motor Water Valve 5V Out 4V Out Bin Control, Control Switch, Low Water Safety High Pressure Switch "AM" LED (X3 Relay) Agitating Motor "COMP