Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  

Majestic Appliances SC36A

Скачали: 94Размер: 346 kb    Производитель: Majestic Appliances  
Категория: Камины

CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with CFM Specialty Home Products approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the CFM Specialty Home Products warranty. In addition, such action may void the coverage provided by the owner’s insurance. Accessory Description Model Number Glass Door — Standard Bi-Fold door set Brushed Brass finish 3

Majestic Appliances Royal Designer Collection STR33

Скачали: 57Размер: 857 kb    Производитель: Majestic Appliances  
Категория: Камины

Majestic® lets you create a gathering place like no other - with the authentic style of a natural woodburning fireplace. The Designer Series offers larger viewing areas than other multi-sided fireplaces. Best of all, they provide generous amounts of radiant heat with no smoke baffles to obstruct your view of the fire. Ready to unleash the designer in you? M MAJESTIC FIREPLACES Framing Width Will be 24' 2 X (Drywall Thickness) STR STB33 STR38 Gas Une Access CL/R36 -40 Vi- (1018mm) — (C

Majestic Appliances SR42A

Скачали: 32Размер: 346 kb    Производитель: Majestic Appliances  
Категория: Камины

(CFM Specialty Home Products manufactures a wide variety of gas logs for use in CFM Specialty Home Products fireplaces.) Be sure to have the appliance installed in accordance with building codes. Gas connection may enter from either left or right side of the fireplace. Locate appropriate gas line in the outer casing of fireplace and remove insulation from gas line tube. (Fig. 26) From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" s

Majestic Appliances RDV4136

Скачали: 29Размер: 5 mb    Производитель: Majestic Appliances  
Категория: Камины

Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo NO 1/8" Gap To Pilot Hood Needed. • All Wiring Connections • Replace Piezo Ignitor • For Air In The Lines • Thermopile Needs A Min. 325m V. Adjust Pilot Flame Height. NO • All Wiring Connections • Replace Thermopile • Thermocouple Needs A Min. Of 14m V • Valve Is Turned On • Wall Switch Is Not Turned On. Watch For Grounded Wires! • Thermopile Needs A Min. 325m V. • Plugged Burner Orifice • Defective Valve. Turn to Pil

Majestic Appliances Woodland UVLC18

Скачали: 28Размер: 1 mb    Производитель: Majestic Appliances  
Категория: Камины

UVLCLogSet Woodland Vent-Free Gas Logs The real beauty is within. Majestic.s Woodlands Collection Vent-Free gas logs give you the appearance of natural wood – right down to a remarkably realistic flame – without any of the inconveniences. No need to cut wood or clean ashes. A simple turn of the knob or press of a button produces an instant fire that burns as long as you want…safely and efficiently. Exclusive Majestic Advantages: • CSA design certified to assure a safe, quality product • The most

Majestic Appliances 360DVS3

Скачали: 24Размер: 3 mb    Производитель: Majestic Appliances  
Категория: Камины

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/or local authorities having jurisdiction for installations above 4,500 feet (1,370 m). Gas Line Installation When purging the gas lines, the window frame assembly must be removed. The gas pipeline can be brought in through the vent end of the fireplace as well as the bottom. Knockouts (to allow

Majestic Appliances BC36

Скачали: 22Размер: 1 mb    Производитель: Majestic Appliances  
Категория: Камины

6. A guy wire stabilizer is required for chimneys extending more than 6' (1.8 m) above a roof line. Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 8) The key points of the "Ten Foot Rule" are: 1. If the horizontal distance from the chimney t

Majestic Appliances SC42A

Скачали: 21Размер: 346 kb    Производитель: Majestic Appliances  
Категория: Камины

MH6018 CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 • DO NOT DISCARD THIS MANUAL: Retain for future use. 7412948

Majestic Appliances SR36A

Скачали: 15Размер: 346 kb    Производитель: Majestic Appliances  
Категория: Камины

When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted. When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 17) 7412948 11 SR/SC Series "A" Woodburning Fireplace Continue install

Majestic Appliances 3375

Скачали: 14Размер: 519 kb    Производитель: Majestic Appliances  
Категория: Электрообогреватели

If necessary, use only a cleaning agent formulated specifically for use on porcelain enamel surfaces. WARNING Turn the burner Pilot OFF before applying paint. NEVER paint pilot or around pilot area. WARNING Dust and debris accumulation can result in poor performance. Inspect the Valve compartment, burner parts and log set frequently and Clean these parts monthly or as often as accumulation warrants. Vermont Castings Radiance Vent-Free Gas Heater Catalytic Combustor The combustor should be cleane





Категории