Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель HP NetServer LC 3

Производитель: HP
Размер: 589.38 kb
Название файла:
Язык инструкции:enfr
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


LANs:
Client LAN
Any NIC that is HP and Microsoft approved. See Client LAN below.
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended.
Intra-cluster
Embedded NIC with crossover cable, or, configure as a VLAN through an
(Heartbeat) LAN
ethernet switch. See Intra-cluster LAN below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.02 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LH 3000
Clock speed
733, 800, 933 MHz
No. of CPUs
2
BIOS version
4.06.21 PT or later (733 MHz)
4.06.24 PT or later (800, 933 MHz)
CPU cache
Any size
RAM
256 MB minimum. Must be HP.
No. of power supplies
2 standard, 3 required for redundancy, 4 for power cord redundancy.
Local storage
See Local Storage below.
I/O slot
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8,
PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
M/S Certified Configuration:
Configuration
P5 - Local Storage – NetRAID-1Si
P6 – Client LAN
P8 – Shared Storage- FC HBA
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si.
For SPOFless, recommend embedded DAC with drives in RAID-1 mirror,
or another fault tolerant RAID level.
Driver
For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
version 5.00.2134.1 or later.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later).
Cabinets (Physical drive
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
location)
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed)
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
2


...

Эта инструкция также подходит к моделям:
Компьютеры - HP NetServer LC 2000 (589.38 kb)
Компьютеры - HP NetServer LC 2000r (589.38 kb)
Компьютеры - HP NetServer LC II (589.38 kb)
Компьютеры - HP NetServer LC Plus (589.38 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории