Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель HP NetServer LC 3

Производитель: HP
Размер: 198.92 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
8 maximum per NetRAID-3Si adapter
Configuration
Cluster mode on
options:
Cache write-policy to Write-thru
Set any other options as desired
Cabinet
RAID arrays
A RAID array (logical disk) must be composed of all the same disk model
(i.e., part number and suffix). Different size or speed disks are not allowed
in the same RAID array. Any combination of disk models is allowed on a
SCSI channel. Any combination of disk models is allowed in a cluster.
No. of cabinets
1 – 3
Model
Rack Storage/12 D5989B or C plus two D6025B’s or two D6025C’s for each
Rack Storage/12
Status SCSI ID
5 (fixed)
Disk SCSI Ids
0 – 3, 8 – 15 (fixed)
Disk drives:
Any HP drive supported by storage enclosure including:
HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A
HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A
HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A
HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A
HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A
HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A
HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A
HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A
HP 18.2 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D7174A
HP 18.2 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D7175A
HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A
HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A
Cables
Any 2 HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or
Any LAN
equivalent
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable. It may not be
used for client communication.
NIC:
Model
HP D5013A/B (10/100TX PCI)
Any that is on both the HP Tested
3


...

Эта инструкция также подходит к моделям:
Компьютеры - HP NetServer LC 2000 (198.92 kb)
Компьютеры - HP NetServer LC 2000r (198.92 kb)
Компьютеры - HP NetServer LC II (198.92 kb)
Компьютеры - HP NetServer LC Plus (198.92 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории