Производитель: HP
Размер: 1.16 mb
Название файла:
|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
601
MESSA
GE
The
PTAPE
intrinsic
is
not
a
v
ailable
on
MPE/iX.
MODE
CM
and
NM
incompatibilit y
detected
b
y
MPT
(sev
erity
lev
el
ERROR),
OCA,
and
R
TM
(Ev
en
t
Class
6).
CA
USE
Mo dications
ha
v
e
b een
made
to
the
attac
hed
p eripheral
en
vironment
of
MPE/iX,
resulting
in
pap er
tap e
readers
b eing
unsupp orted
on
MPE/iX-based
computer
systems.
The
PTAPE
intrinsic
is
not
supp orted
on
MPE/
iX-based
computer
systems.
A
CTION
Remov
e
all
PTAPE
inv
o cations
and
dep enden
t
co de.
If
y
ou
are
using
PTAPE
for
uses
other
than
reading
from
pap er
tap e
devices,
y
ou
must
determine
the
original
need
for
the
call
to
PTAPE
and
dev
elop
alternative
solutions.
602
MESSA
GE
The
FCARD
intrinsic
is
not
a
v
ailable
on
MPE/iX.
MODE
CM
and
NM
incompatibilit y
detected
b
y
MPT
(sev
erity
lev
el
ERROR),
OCA
,
and
R
TM
(Ev
en
t
Class
6).
CA
USE
Mo dications
ha
v
e
b een
made
to
the
attac
hed
p eripheral
en
vironment
of
MPE/iX;
the
HP
7260
series
of
card
readers
is
not
supp orted
on
MPE/iX-based
computer
systems.
Because
the
FCARD
intrinsic
accesses
only
these
card
readers,
FCARD
likewise
is
not
supp orted
on
MPE/iX.
A
CTION
Remov
e
all
FCARD
inv
o cations
and
dep enden
t
co de.
604
MESSA
GE
FDEVICECONTROL
intrinsic
c
ontr
olc
o
de
parameter
v
alue
of
192.
MODE
CM
and
NM
incompatibilit y
detected
b
y
MPT
(sev
erity
lev
el
W
ARNING)
and
OCA.
CA
USE
FDEVICECONTROL
with
c
ontr
olc
o
de
of
192
is
used
for
devices
connected
through
the
terminal
subsystem.
Mo dications
ha
v
e
b een
made
to
the
terminal
subsystem
of
MPE/iX,
resulting
in
FDEVICECONTROL
b eing
unsupp orted
for
these
devices
on
the
1.0
v
ersion
of
MPE/iX-based
computer
systems.
A
CTION
If
y
ou
are
migrating
to
the
1.0
release
of
MPE/iX,
remo
v
e
all
FDEVICECONTROL
calls
using
a
c
ontr
olc
o
de
of
192
and
dep enden
t
co de.
Ev
aluate
y
our
original
need
for
FDEVICECONTROL
and
determine
alternative
solutions.
Some
of
the
functions
of
suc
h
calls
are
no
longer
necessary;
for
example,
c
hanges
to
ENQ/A
CK
proto col
are
not
needed
since
this
proto col
is
not
used
on
MPE/iX.
Other
functions
that
FDEVICECONTROL
pro
vides
are
also
a
v
ailable
through
the
FCONTROL
intrinsic,
suc
h
as
using
parit
y
c
hec
king
and
setting
new
v
alues
for
the
Subsystem
Break
or
Alternate
End-of-Record.
Incompatibilities
D-37
On
release
1.1
or
later,
FDEVICECONTROL
with
con
trol
co de
192
and
its
dep enden
t
co des
is
implemen
ted
as
on
MPE
V,
with
the
exception
of
Alternate
End-of-Record.
On
MPE
V
systems,
y
ou
are
allow
ed
to
designate
multiple
AEOR
c
haracters
for
a
single
device.
MPE/iX,
ho
w
ev
er,
allo ws
y
ou
to
designate
only
one
AEOR
c
haracter
for
a
device
at
an
y
given
time.
Mo dications
may
b e
necessary
to
pro
vide
only
one
AEOR
c
haracter
in
existing
co de.
F
or
more
information
refer
to
MPE
XL
Asynchr
onous
Serial
Communic
ations
Pr
o
gr
ammer's
R
efer
enc
e
Manual
(32022-90012)
for
further
information.
...Эта инструкция также подходит к моделям:
Программное обеспечение - MPE/iX 6.5 Operating System (1.16 mb)