Инструкция по эксплуатации HP, модель MPE/iX 6.0 Operating System

Производитель: HP
Размер: 941.62 kb
Название файла:
Язык инструкции:itenesfrdept
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


T
o
understand
processor
bay
card
cages
As
a
system
manager,
y
ou
may
b e
in
terested
in
kno
wing
what
is
inside
the
pro cessor
ba
y
.
This
information
should
help
y
ou
b ecome
familiar
with
the
system.
The
pro cessor
ba
y
houses
the
pro cessor
and
memory
card
cages
in
the
fron
t
of
the
pro cessor
ba
y
and
the
mid-bus
and
I/O
card
cages
in
the
rear
of
the
pro cessor
ba
y
.
These
card
cages
are
where
the
v
arious
pro cessor,
memory
,
c
hannel
adapter,
and
CIO
device
adapter
cards
reside.
The
system
manager
nev
er
needs
to
access
inside
the
Series
950
through
Series
980
computer
system.
Servicing
the
system
is
p erformed
b
y
qualied
Hewlett-Pac
k
ard
supp ort
p ersonnel.
Series
950
through
Series
980
systems
can
use
64-Mbyte
memory
array
cards
in
addition
to
16-Mbyte
memory
array
cards.
CIO
device
adapter
cards
residing
in
the
CIO
card
cages
are
the
HP-IB,
m
ultiplexer
(MUX),
LAN
in
terface
con
troller
(LANIC),
and
access
p ort
(AP).
The
p eripherals
are
accessed
b
y
a
path
address
that
is
dened
b
y
the
card
cage
and
slot
n
um
b er
that
the
device
adapters,
c
hannel
adapters,
and
bus
con
v
erters
o ccup
y
.
T
o
understand
the
Uninterruptible
P
o
w
er
Supply
(UPS)
The
Series
9X8
systems
and
the
Series
991
and
995
systems
use
the
HP
mo
del
A2998A
P
o
w
erT
rust
UPS
(Unin
terruptible
P
o
w
er
Supply)
unit
for
p o
w
erfail
protection.
Lik
e
the
battery
bac
kup
metho d
of
p o
w
er
failure,
the
UPS
devices
protect
the
HP
3000
system
against
the
loss
of
\work
in
progress"
in
cases
of
utilit y
A
C
p o
w
er
failures
of
up
to
fteen
min
utes
in
duration.
F
urthermore,
they
ha
v
e
b een
designed
to
app ear
similar
to
the
Battery
Bac
kup
metho d
whic
h
minimizes
their
eect
on
system
op eration
and
managemen
t
pro cedures.
UPS
devices
do
oer
t
w
o
principal
adv
an
tages
o
v
er
the
Battery
Bac
kup
metho d:
In
a
minimal
UPS-based
system,
the
degree
of
p o
w
er
failure
protection
is
equiv
alen
t
to
that
of
the
battery
bac
kup
unit.
Y
ou
can,
ho
w
ev
er,
add
more
UPS
devices
to
the
system
and
pro
vide
reserv
e
p o
w
er
to
selected
p eripherals.
Dep ending
up on
ho
w
m
uc
h
of
the
system
is
pro
vided
with
UPS
p o
w
er,
it
can
run
a
partial
or
full
w
orkload
non-stop
through
limited
p erio
ds
of
A
C
p o
w
er
failure.
The
UPS
con
tains
a
serial
I/O
comm
unications
in
terface
that,
in
conjunction
with
UPS
Monitor/iX
softw
are,
noties
the
system
op erator
of
an
y
problems.
In
addition
to
console
messages,
the
UPS
Monitor/iX
softw
are
also
p osts
a
v
ariety
of
status
and
w
arning
messages
to
the
system
log
les
whic
h
y
ou
can
review
and
analyze
to
ev
aluate
system
p erformance.
Y
ou
add
UPS
devices
to
the
I/O
conguration
using
the
No de
Management
Services
Conguration
Manager
(NMMGR)
program.
(Refer
to
c
hapter
3
of
this
man
ual
for
a
brief
in
tro
duction
and
read
Conguring
Systems
for
T
erminals,
Printers,
and
Other
Serial
Devic
es
(32022-90001)
for
detailed
information.)
Once
y
ou
ha
v
e
congured
the
UPSs,
the
UPS
Monitor/iX
softw
are
con
tinuously
monitors
the
condition
of
all
UPS
devices
on
the
system.
F
urthermore,
it
em
ulates
the
p o
w
er
failure
reco
v
ery
b eha
vior
of
systems
using
battery
bac
kup
units:
Up on
the
return
of
p o
w
er
following
a
failure,
UPS
Monitor/iX
broadcasts
a
system-wide
p o
w
er
failure
reco
v
ery
message
to
all
active
user
terminals
and
to
the
console.
12-16
System
Hardw
are
Descriptions


...

Эта инструкция также подходит к моделям:
Программное обеспечение - MPE/iX 6.5 Operating System (941.62 kb)
Программное обеспечение - MPE/iX 7.0 Operating System (941.62 kb)
Программное обеспечение - MPE/iX 7.5 Operating System (941.62 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории