Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Yamaha, модель M7CL-48

Производитель: Yamaha
Размер: 11.64 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


• The Focus function can be used in conjunction with the Recall Safe function (> p. 136). Channels or parameters that are excluded from Recall operations by either Focus or Recall Safe will not be recalled. 12 Scene 135 M7CL Owner’s Manual Using the Recall Safe function Using the Recall Safe function Using the Recall Safe function Using the Recall Safe function “Recall Safe” is a function that excludes only specific parameters/channels (DCA groups) from Recall operations. This differs from the Focus settings (> p. 135) made for individual scenes in that Recall Safe settings are common to all scenes. 1 In the function access area, press the CH JOB button to access the CH JOB popup window. RECALL SAFE button 2 Press the RECALL SAFE button to access the RECALL SAFE MODE popup window. In this popup window you can make settings for the Recall Safe function. The window contains the following items. 1 2 54 3 1 CH RECALL SAFE field The channels and DCA groups for which Recall Safe is turned on are highlighted in this field. If you turn on the SET BY SEL button, you can turn on Recall Safe for a channel or DCA group simply by pressing the [SEL] key of that channel or DCA group. B CLEAR ALL button This clears all Recall Safe settings for the channels or DCA groups that are highlighted in the CH RECALL SAFE field. C GLOBAL RECALL SAFE field Press the buttons in this field to select the global parameters (i.e., parameters that apply to the entire mix, rather than to specific channels) that will be set to Recall Safe. D SAFE PARAMETER SELECT field Here you can switch Recall Safe on/off for the desired channels or DCA groups, and choose the parameters that will be excluded from Recall operations. The channel or DCA group you selected by pressing its [SEL] key will be shown in this field as the target of your operations. If you press any of the [SEL] keys of the DCA groups, the parameters for DCA groups 1–8 will be shown simultaneously. E APPLY TO ALL INPUT button / APPLY TO ALL OUTPUT button If these buttons are on when you operate the SAFE PARAMETER SELECT buttons, the changes will apply to all input (or output) channels. This is convenient when you want to make settings for all channels together. HINT • The RECALL SAFE MODE popup window can also be accessed from the SELECTED CHANNEL VIEW screen’s RECALL SAFE field (> p. 85). 3 To select the channel or DCA group whose Recall Safe settings you want to edit, press the corresponding [SEL] key. The corresponding channel or DCA group will be enclosed by a white frame in the CH RECALL SAFE field. (However, this white frame does not mean that the Recall Safe setting is now enabled.) The selected channel or DCA groups 1–8 will be recalled to the SAFE PARAMETER SELECT field. HINT • If the CH RECALL SAFE field’s SET BY SEL button is on, Recall Safe will be enabled when you press the [SEL] key, and the corresponding channel or DCA group will be highlighted in the CH RECALL SAFE field. You can select parameters as described in step 4 even after turning Recall Safe on. 4 If you want to enable Recall Safe for specific parameters of the selected channel or DCA group, make the following settings in the SAFE PARAMETER SELECT field. NOTE • Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on/off, you must also perform the operation of step 5. HINT • While the APPLY TO ALL INPUT button (or the APPLY TO ALL OUTPUT button) is on, operations in the SAFE PARAMETER SELECT field will apply to all input channels (or output channels). M7CL Owner’s Manual Using the Recall Safe function Using the Recall Safe function If an input channel is selected Use the buttons in the lower part of the SAFE PARAMETER SELECT field (except for the “ALL” button) to select the parameters that will be subject to Recall Safe (multiple selections are allowed). If you want all parameters to be subject to Recall Safe, turn on the ALL button (this is the default setting). These buttons correspond to the following parameters. Button name Corresponding parameters ALL All parameters HA Head amp settings (including external HA) EQ EQ settings (including ATT/HPF) DYNA 1 Dynamics 1 settings DYNA 2 Dynamics 2 settings MIX ON On/off status of signals sent to MIX buses MIX SEND Send levels of signals sent to MIX buses MATRIX ON On/off status of signals sent to MATRIX buses MATRIX SEND Send levels of signals sent to MATRIX buses FADER Fader positions CH ON On/off status of [ON] keys NOTE • If the ALL button is on, all other buttons in the lower part of the SAFE PARAMETER SELECT field will be turned off. . If a STEREO/MONO channel is selected With the exception of the types of button that are displayed, this is the same as for an input channel. These buttons correspond to the following parameters. Button name Corresponding parameters ALL All parameters EQ EQ settings (including ATT) DYNA 1 Dynamics 1 settings MATRIX ON On/off status of signals sent to MATRIX buses MATRIX SEND Send levels of sign...

Эта инструкция также подходит к моделям:
Музыкальные инструменты - M7CL-32 (11.64 mb)
Музыкальные инструменты - M7CL-48ES (11.64 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории