Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Yamaha, модель M7CL-48ES

Производитель: Yamaha
Размер: 13.09 mb
Название файла:

Язык инструкции:enesca

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста


К этому устройству также есть другие инструкции:

Фрагмент инструкции


If the recalled scene memory and effect library has been assigned to more than one program number, the lowest-numbered program number for each MIDI channel will be transmitted. Program Change messages are not used for transmission to M7CL Editor because there is no guarantee that the contents of the assignment tables will match. (Parameter Change messages are always used.) You can choose either MULTI MIDI CH or SINGLE CH. If SINGLE is selected You can choose the RX CH, OMNI CH, and TX CH. You can choose whether a bank select message will be added. A bank of up to 16 can be specified. If MULTI is selected The RX and TX channels will be the same. The assignment table will use the settings for each MIDI channel. Bank select messages will not be added. You can make settings for up to sixteen MIDI channels. STATUS 1100nnnn Cn Program change DATA 0nnnnnnn nn Program number (0-127) 2 SYSTEM REALTIME MESSAGE 2.1 TIMING CLOCK (F8) Reception This message is used to control effects. This message is transmitted twenty-four times per quarter note. Echoing of this message depends on the OTHER item in the ECHO settings. STATUS 11111000 F8 Timing clock 2.2 ACTIVE SENSING (FE) Reception Once this message has been received, MIDI communication will be initialized (e.g., Running Status will be cleared) if no message is received for an interval of 400 ms. This message is not subject to echoing. STATUS 11111110 FE Active sensing 2.3 SYSTEM RESET (FF) Reception When this message is received, MIDI communication will be initialized (e.g., Running Status will be cleared). This message is not subject to echoing. STATUS 11111111 FF System reset 3 System Exclusive Message 3.1 Bulk Dump Command rx/tx function F0 43 0n 3E BB BB 11 D0 D1 D2 … rx/tx BULK DUMP EE F7 BULK DUMP DATA DATA F0 43 2n 3E 11 D0 D1 D2 F7 rx BULK DUMP BULK DUMP REQUEST REQUEST The M7CL uses the following data types for a bulk dump. Data name (D0) Data Number (D1,2) tx/rx function ‘M’ 0–300, 512, 768 tx/rx Scene Memory & Request ‘S’ 512–517 tx/rx Setup Memory & Request (current setup) ‘s’ 512–528 tx/rx User Setup Memory & Request ‘Y’ 1–199, 512– tx/rx Dynamics library & Request ‘H’ 0–199, 512–559, tx/rx Input Channel library & Request 560-567 ‘h’ 0–199, 768–783, tx/rx Output Channel library & 1024–1031, Request 1280–1282 ‘Q’ 1–199, 512– tx/rx Input Equalizer library & Request ‘q’ 1–199, 768– tx/rx Output Equalizer library & Request ‘F’ 1–199, 512– 527 tx/rx GEQ Equalizer library & Request ‘E’ 1–199, 512– 515 tx/rx Effect library & Request ‘P’ 512 tx/rx Program change table & Request ‘C’ 512 tx/rx Control change table & Request ‘M’ 0–300 Scene number 512 Current Data (without Recall Safe) 768 Current Data (with Recall Safe) ’S’ 512 Setup Memory 513 Mixer Setting 514 Output Port 515 Monitor 516 MIDI Setting 517 Library Number ’s’ 512–515 User Defined Key 1–4 516–519 User Defined Key Guest 1–4 520–523 User Defined Key Admin 1–4 524 Preference 525 User Key 526 User Key Guest 527 Preference Guest 528 Preference Admin ‘Y’ 1–199 Library number 512–559 Dynamics1 Input 1–48 560–567 STIN 1L–4R 768–783 MIX 1–16 1024–1031 MATRIX 1–8 1280–1282 STEREO L,R,MONO(C) 1536–1583 Dynamics2 Input 1–48 1584–1591 STIN 1L–4R ’H’ 0–199 Library number 512–559 Input 1–48, 560–567 STIN 1L–4R ’h’ 0–199 Library number 768–783 MIX 1–16 1024–1031 MATRIX 1–8 1280–1282 STEREO L,R,MONO(C) ’Q’, ’q’ 1–199 Library number 512–559 Input 1–48, 560–567 STIN 1L–4R 768–783 MIX 1–16 1024–1031 MATRIX 1–8 1280–1282 STEREO L,R,MONO(C) ‘F’ 1–199 Library number 512–527 RACK 1A–8B ‘E’ 1–199 Library number 512–515 RACK 5–8 ’P’, ’C’ 512 Current Data Data is lost when you write to the preset library. The unique header (Model ID) identifies whether the device is a M7CL. To calculate the check sum, add the bytes starting with the byte after BYTE COUNT (LOW) and ending with the byte before CHECK SUM, take the binary complement, and set bit 7 to 0. CHECK SUM = (-sum)&0x7F Bulk Dumps can be received at any time, and can be transmitted at any time when a Bulk Dump Request is received. A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump Request. In the data portion, seven words of 8-bit data are converted into eight words of 7-bit data. Apendices 283 M7CL Manual de instrucciones Formato de datos MIDI Formato de datos MIDI d[0. 6]: actual data b[0. 7]: bulk data b[0] = 0; for( I=0; I<7; I++){ if( d[I]&0x80){ b[0] |= 1<<(6-I); } b[I+1] = d[I]&0x7F; } [Recovery from bulk data to actual data] d[0. 6]: actual data b[0. 7]: bulk data for( I=0; I<7; I++){ b[0] <<= 1; d[I] = b[I+1]+(0x80&b[0]); } 3.2 PARAMETER CHANGE Reception This message is echoed if [Parameter change ECHO] is ON. This message is received if [Parameter change RX] is ON and [Rx CH] matches the Device number included in the SUB STATUS. When a parameter change is received, the specified parameter will be controlled. When a parameter request is received, the current value of the specified parameter will be transmitted as a parameter change with it...

Эта инструкция также подходит к моделям:
Музыкальные инструменты - M7CL-32 (13.09 mb)
Музыкальные инструменты - M7CL-48 (13.09 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории