Keep burner and control compartment clean. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles burning
Bend out the four nailing tabs, attached on either side of the fireplace and secure to the 2x4 framing. The tabs will facilitate the installation of either a 3/4” or a 1” finished surface thickness. The nailing tabs must not be removed. NAILINGNAILING TABTAB FIGURE 10 W415-0369 / E / 02.16.07 FINISHING LOG PLACEMENT FINISHING LOG PLACEMENT PHAZERTM logs are exclusive to NAPOLEON® Fireplaces, and provide a unique and realistic glowing effect that is different in every installation. Log colours ma
N PROPANE GAS MODEL GVF36P CERTIFIED FOR UNITED STATES USING ANSI METHODS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your bu
W415-0297 / D / 04.03.03 FINISHING LOGO PLACEMENTHOOD HOOD CURTAIN MESH FIGURE 11 FINISHING LOGO PLACEMENTHOOD HOOD CURTAIN MESH FIGURE 11 The curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring. FIGURE 12 The heater must not be used when the hood is removed. Hook the hood over the lip of the curtain support plate. Remove the backing of the logo supplied and place on the screen cover, as indicated. FIGURE 13 CATALYTIC DOOR OPENING & CLOSING DOO
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. Installation and service must be performed by a qualified installer, service agency or the gas supplier. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot
Level using four of the levelling screws. See Figure 1a. Levelling the unit will eliminate rocking or excessive noise when the fan is in operation. Once the unit is level, move it partially into place within the fireplace to allow for all connections to be made. It is not practical to level the insert once it has been installed. Determine the required depth prior to installing the unit and adjust the four levelling screws accordingly. Chimney installation must conform to both national and local
Imagine the warm glow from the PHAZer® log set and the luxurious heat - Life is good! Accent your backyard area and immerse yourself in the enjoyment of outdoor living. The GSS42 features heat resistant glass doors and shimmering stainless steel trim. Designer Options Decorative sandstone brick panels remote ControlFeatures and Benefits • 100% stainless steel construction for maximum durability • No venting or chimney required, making installationa simple process• Up to 65,000 BTU’s of warm, lux
Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch.
ALL HORIZONTAL RUNS MUST HAVE A MINIMUM . INCH RISE PER FOOT. 1. Stretch the 4" diameter aluminum flexible liner to the required length taking into account the additional length needed for the finished wall surface. Spacers are attached to the 4" inner flex liner at predetermined intervals to maintain a 1-1/4" air gap to the 7" outer stove pipe. These spacers must not be removed. Slip a 4" diameter length of aluminum flexible liner a minimum of 2" over the inner sleeve of the air terminal. Secur
..... • It is imperative that the control compartments, burners and circulating blower and its passageway in the stove • It is imperative that the control compartments, burners and circulating blower and its passageway in the stove• It is imperative that the control compartments, burners and circulating blower and its passageway in the stove• It is imperative that the control compartments, burners and circulating blower and its passageway in the stove• It is imperative that the control compartme