Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Napoleon Grills, модель GDI-44P

Производитель: Napoleon Grills
Размер: 919.22 kb
Название файла: fbace0c8-e022-455d-8097-ccb38a858ee6.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Level using four of the levelling screws. See Figure 1a. Levelling the unit will eliminate rocking or excessive noise when the fan is in operation. Once the unit is level, move it partially into place within the fireplace to allow for all connections to be made. It is not practical to level the insert once it has been installed. Determine the required depth prior to installing the unit and adjust the four levelling screws accordingly. Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 2" or 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum vent lengths are 10 and 35 feet respectively. Recommended Napoleon kits come in 3 lengths: While the liners must be continuous from the fireplace to the chimney cap, to achieve the needed length, they may be coupled, using an aluminium coupler, provided installation is sealed & secured. We recommend that exhaust vents that pass through unheated spaces, such as a garage or attic, be wrapped in a protective sleeve to minimize condensation and reverse flow symptoms. This unit is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance, however, it is recommended to use two 3" liners. If a 2" liner is used for the intake, it is necessary to adjust the primary air shutter. See "Air Shutter Settings". 1. OUTSIDE: Slip the one end of a liner a minimum of 2" over the collar of the air terminal. Secure using 3 screws. Then seal the joint and screw heads with high temperature sealant. Repeat with the other liner to the exhaust collar of the terminal. NOTE: Connect the supplied 3' of stainless steel flexliner to the exhaust liner (already attached to the terminal) using the coupler (also supplied). Secure and seal before dropping down the chimney. FIGURE 4 VENT CONNECTION ASSEMBLY FIGURE 6 INSERT VENT CONNECTION CHIMNEY CONNECTION 1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST & 2-3" TO 2" REDUCER: GDI-2320KT VENT KIT 20FT GDI-2325KT VENT KIT 25FT GDI-2335KT VENT KIT 35FT 2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST: GDI-320KT VENT KIT 20FT GDI-325KT VENT KIT 25 FT GDI-335KT VENT KIT 35 FT FIGURE 2 ALUMINUM FLEXLINER COUPLER STAINLESS STEEL FLEXLINER FIGURE 3 7 W415-0314 / C / 01.15.04 For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt thermostat. The recommended maximum lead length depends on the wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Do not connect either the wall switch, thermostat or gas valve to electricity (110 VOLTS). To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and retighten screws. There is also a very slight in/out adjustment that can be made. Note: Since the side panels open and close, to access the controls, a gap is necessary at the mitre joint. The top trim piece has an adjustable securing bracket which enables the trim to be secured to the firebox shell. In order to close off the fireplace opening or if the opening is larger than the 3- or 4-sided aluminium extrusion trim kits, it is recommended to reduce the opening using a noncombustible material such as ceramic tile, marble, etc or the GDIBP3 or GDIBP4 backer plate kits. The GDIBP3 backer plate is able to fit an opening of 52" x 33.". The GDIBP4 backer plate is able to fit an opening of 52" x 42.". The outside edge of the backer plate is finished off with gold trim included in each kit. A GDIBP3D 3 sided deluxe backer plate complete with marquis trim may also be used to complete the installation. This kit is able to fit an opening of 57" x 33.". Detailed installation instructions are included with each kit. If this unit is being installed into an existing wood burning, zero clearance fireplace, then be aware of this precaution: Any circulation air opening may be covered (with material) but not sealed! The insert can be equipped with either a 3- or 4-sided trim kit to finish off the fireplace opening. Slide the trim assembly over the keyholes (2 per side) and drop into place. If installing the optional 3- or 4-sided backer plate (GDIBP3 or GDIBP4), it must be hung prior to the trim kit installation using the same keyholes. FIGURE 10 FIGURE 12 LOOSEN SCREWS SLIDE TO ADJUST FIGURE 13 FIGURE 11 VENT CONNECTION ASSEMBLY FIGURE 7 FINISHING ALUMINIUM EXTRUSION TRIM KIT INSTALLATION 6. Reinstall the back wall, followed by the log support, using the perimeter screws removed in step 4. Install suitable supply piping connection to the 3/8" flex connector supplied (as per local gas codes). GAS INSTALLATION The insert may now be pushed into its final position inside the wood-burning fireplace. Secure the insert to the fireplace using perforated s...

Эта инструкция также подходит к моделям:
Камины - GDI-44N (919.22 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории