Войти:
Скачали: 36   Размер: 5 mb   Производитель: Enviro  
Категория: Камины
@name

Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier. FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fi re department. Tested by: Installer: Please complete the details on the back cover a

Скачали: 5   Размер: 5 mb   Производитель: Enviro  
Категория: Камины
@name

Use a non-abrasive cleaner and NEVER clean the glass while it is hot. AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue flame or close for a more yellow flame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. This adjustment is performed by the gas fitter. Minimum Air Shutter Opening: 5/16" Natural Gas 3/8" Pro

Скачали: 0   Размер: 3 mb   Производитель: Enviro  
Категория: Камины
@name

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. 50-765 Table of Contents Introduction......................................................................................................................................3 Pellet Quality.........................................................................................................................3 Rating Label Location......................................................................

Скачали: 0   Размер: 3 mb   Производитель: Enviro  
Категория: Камины
@name

Do not pack air spaces with insulation. 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting syst

Скачали: 5   Размер: 3 mb   Производитель: Enviro  
Категория: Камины
@name

CLEARANCES TO COMBUSTIBLES: A. Sidewall to unit 11 inches (27.9 cm) B. Backwall to unit 2.5 inches (6.35 cm) C. Corner to unit 2.5 inches (6.35 cm) D. Ceiling 60 inches above floor (152.4 cm) E. Floor (hard wood and linoleum) 0 inches Note: When installing on a carpeted surfaces a non- combustible hearth pad must be used. Minimum Alcove Dimensions: Width 48 inches (121.9 cm) Height 60 inches (152.4 cm) Depth (max) 24 inches (60.96 cm) CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE

Скачали: 2   Размер: 3 mb   Производитель: Enviro  
Категория: Камины
@name

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE EF3 Freestanding, Fireplace Insert, and Built-In Heater OWNER’S MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. EF-118 Table of Contents Introduction..................

Скачали: 5   Размер: 2 mb   Производитель: Enviro  
Категория: Камины
@name

INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements. 2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall. 3. Project

Скачали: 16   Размер: 2 mb   Производитель: Enviro  
Категория: Камины
@name

With the Drafthood Adaptor correctly installed and wired to the gas control valve. Your Direct Vent Fireplace can be vented like a B-Vent Fireplace. INSTALLATION: WARNING: This Freestanding Drafthood Adaptor must be fitted by a qualified service technician. Step 1 Remove the Drafthood Adaptor from the packaging. Ensure the unit and wire harness are undamaged. If there is damage contact your dealer, distributor, or courier company before starting this installation. Step 2 Install the adaptor so t

Скачали: 4   Размер: 2 mb   Производитель: Enviro  
Категория: Камины
@name

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Haven DIRECT VENT FIREPLACE BY: SHERWOOD INDUSTRIES LTD OWNER’S MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows/extinguish any open flame. • Do not try to light any appliance. • Do not touch any electrical switch or use any phone in your building. • Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. This appliance may be instal

Скачали: 48   Размер: 2 mb   Производитель: Enviro  
Категория: Камины
@name

123/8" (315mm) 55/16" (135mm) 45o3415/16" (887mm) 401/4" (1022mm) Figure 17. Dimensions for Framing the Firebox. Table 3. Inlet Placement Dimensions, refer to Figure 1. Side Inlet: Gas Electrical Distance back 63/16” 15.8 cm 81.2 21.5 cm Distance up 15.8” 4.1 cm 111/16” 4.3 cm Bottom Inlet: Gas Electrical Distance back 59/16” 14.1 cm 811/16” 22.0 cm Distance from side 37.8” 9.8 cm 43.4” 12.1 cm Figure 18. Dimensions for Top Framing the Firebox. 1 The gas line, 3.8 inch NPT, can be brought to eit





Категории