Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Napoleon Grills, модель GDI-44N

Производитель: Napoleon Grills
Размер: 919.22 kb
Название файла: fbace0c8-e022-455d-8097-ccb38a858ee6.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. Installation and service must be performed by a qualified installer, service agency or the gas supplier. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 • ask@napoleon.on.ca W415-0314 / C / 01.15.04 TABLE of CONTENTS TABLE of CONTENTS Pg 2-4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5-7 INSTALLATION Insert Vent Connection Chimney Connection Gas Pipe Installation Wall Switch / Thermostat 7-8 FINISHING Trim Extrusion Installation Log Placement Ember Placement Door Installation Mantle Clearances Pg 9-10 OPERATION / MAINTENANCE Operating Instructions Rear Burner Control Maintenance 10 REPLACEMENT BLOWER 11 ADJUSTMENTS Pilot Burner Adjustment Vent Restrictions Venturi Adjustments 12-13 REPLACEMENTS Ordering Replacement Parts Replacement Parts Terminal Kits Accessories 14-15 TROUBLE SHOOTING GUIDE 16 SERVICE HISTORY PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE WARNING • The fireplace insert is a vented gas-fired heater. Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace insert. • Due to high temperatures, the fireplace insert should be located out of traffic and away from furniture and draperies. • Clothing or other flammable material should not be placed on or near the fireplace insert. • Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace insert. • It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace insert and venting system are kept clean. The fireplace insert and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace insert area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. • Under no circumstances should this fireplace insert be modified. • This fireplace insert must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance. • Do not use this fireplace insert if any part has been under water. Immediately call a qualified service technician to inspect the fireplace insert and to replace any part of the control system and any gas control which has been under water. • Do not operate the fireplace insert with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. • Do not strike or slam shut the fireplace insert glass door. • This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. NOTE: changes, other than editorial, are denoted by a vertical line in the margin. W415-0314 / C / 01.15.04 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON. NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new The following materials and workmanship in your newThe following materials and workmanship in your newThe following materials and workmanship in your newThe following materials and workmanship in your newThe following materials and workmanship in your new NAPOLEON NAPOLEONNAPOLEONNAPOLEONNAPOLEONNAPOLEON gas fireplace are gas fireplace aregas fireplace aregas fireplace aregas fireplace aregas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion warranted against defects for as long as you own the fireplace. This covers: combustionwarranted against defects for as long as you own the fireplace. This covers: combustionwarranted against defects for as long as you own the fireplace. This co...

Эта инструкция также подходит к моделям:
Камины - GDI-44P (919.22 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории