Войти:
Скачали: 4   Размер: 219 kb   Производитель: Honeywell  
Категория: Грили
@name

2. Extinguish any flame. 3. Open lid. 4. If odor continues, immediately call your gas supplier or fire department. INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference. BRICK OPENING: 8 3/4" x 14 1/4" x 4" deep. Side shelves and connector kits for mounting side burners on portable carts or in countertop enclosures are packaged separately. SIDEBURNER SHELF MODELS #25326-016 & #25336-016 DROP-IN MODELS #3275 & #3280 INSTALLATION AND OPERATING INSTRUCT

Скачали: 5   Размер: 1 mb   Производитель: Honeywell  
Категория: Грили
@name

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2 Fireye C, D, and E-Series Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6 Fireye P-Series Section III . . . . . .

Скачали: 13   Размер: 489 kb   Производитель: Honeywell  
Категория: Грили
@name

FEATURES • Q179A is a gas pilot assembly with a flame electrode (rod) and ignition electrode, making it suitable for applications requiring an interrupted or intermittent electrically ignited gas pilot burner. • Q179A1183 is an “I” port burner with an ignitionelectrode (spark) only. • Q179B has only the flame electrode and is suitable for use in continuous pilot applications. • Primary aerated type burner is equipped with stainless steel fins that provide the proper flame rod area to ground area

Скачали: 7   Размер: 187 kb   Производитель: Honeywell  
Категория: Грили
@name

Use 221° F [105° C] minimum thermoplastic- insulated wire for the ground leadwire (asbestos insulation is not acceptable). 2. A male 1/4 in. [6 mm] quick-connect terminal is provided on Honeywell ignition modules. Fasten female quick-connect to wire end at ignition module. 3. Strip other end and fasten under igniter-sensor mounting screw. 4. If necessary, use shield to protect lead from radiant heat of burner. 5. The pilot burner serves as the grounding area for the flame signal. Run lead from p

Скачали: 3   Размер: 187 kb   Производитель: Honeywell  
Категория: Грили
@name

Do not impinge main burner flame on pilot burner/ igniter-sensor. 6. Do not expose pilot flame to falling scale, which could impair main burner ignition. 7. Do not expose pilot burner/igniter-sensor to main burner rollout while igniting or extinguishing. 8. Do not expose pilot flame to drafts that push or pull pilot flame away from the igniter-sensor. NOTE: The Q381A Pilot Burner/Igniter-Sensor is for horizontal mounting only. Mounting bracket must remain vertical. G. S. • Rev. 7-93 • ©Honeywell

Скачали: 0   Размер: 187 kb   Производитель: Honeywell  
Категория: Грили
@name

• S8600B,H; S86H only: The pilot lights, the spark stops and main burner lights, but the system locks out. If so, assure adequate flame current as follows: • Turn off furnace at circuit breaker or fuse box. • Clean the flame rod with emery cloth. • Make sure electrical connections are clean and tight. Replace damaged wire with moisture-resistant no. 18 wire rated for continuous duty up to 221° F [105° C]. • Check for cracked ceramic insulator, which can cause short to ground, and replace pilot b

Скачали: 1   Размер: 187 kb   Производитель: Honeywell  
Категория: Грили
@name

PILOT BURNER/IGNITER-SENSOR MUST BE RIGIDLY POSITIONED RELATIVE TO MAIN BURNER M3271 Fig. 1—Mount pilot burner/igniter-sensor on main burner. Fig. 2—Location of pilot burner/igniter-sensor. PILOT BURNER/ PILOT BURNER/ IGNITER- PILOT BURNER/ IGNITER- SENSOR IGNITER- SENSOR JUST RIGHT SENSOR TOO HIGH TOO LOW IGNITION MAIN BURNER JUST MISSES IGNITION FLAME FLAME WILL FLAME WILL MAIN BURNER IMPINGE ON IMPINGE ON MAIN BURNER IGNITION- SENSOR M3273 2. Mount pilot burner/igniter-sensor on main bu

Скачали: 0   Размер: 187 kb   Производитель: Honeywell  
Категория: Грили
@name

Recheck ignition sequence as follows: • Reconnect main valve wire. • Set thermostat to call for heat. • Watch ignition sequence at burner. • If spark still does not stop after pilot lights, replace ignition module. • If main burner does not light or if main burner lights but system locks out, check module, ground wire, and gas control as described in control module instructions. 3 60-0653—8 Fig. 7—Example of unsatisfactory pilot flames. Fig. 7—Example of unsatisfactory pilot flames. APPEARANCE C

Скачали: 5   Размер: 87 kb   Производитель: Honeywell  
Категория: Грили
@name

Location 1. Mount on a 4 in. by 4 in. junction box, directly on the main burner or inside the appliance cabinet. In replacement applications, mount in the same location as the old control. See Fig. 1. Make sure the operating temperatures are within the ambient temperature range (see Specifications section). 2. Before mounting the control, make line voltage connections as shown in Fig. 2 through 7. Splice lines with solderless connectors. Do not exceed load ratings shown on the device label. 3. I

Скачали: 29   Размер: 87 kb   Производитель: Honeywell  
Категория: Грили
@name

The primary controls fuel oil, senses flame, controls ignition spark and notifies a remote alarm circuit when in lockout. The R7184 can be used with both hydronic and forced air systems. When used with hydronic systems, line voltage switching Aquastat® Controllers normally provide for the starting and stopping of the combustion sequences. With forced air systems, both mechanical and electronic low voltage thermostats control the starting and stopping of the combustion process. Some hydronic and