Loose coals and pebbles are packed separately within the carton. When the heater is assembled the coals or pebbles are placed on top of the fuel bed. ‘The coals may be removed and pebbles added in their place up to a maximum weight of 6KG. The heater is designed for use inset into a 407mm (16") or 457mm (18") wide by 559mm (22") high fireplace opening see also section “Installation in a fire place opening”. A 2kw fan heater discreetly positioned in the canopy of the fire provides heating in cold

Скачали: 8   Размер: 200 kb   Производитель: Dimplex  
Категория: Вентиляторы
@name

GREEN/YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE Connect the Green/Yellow wire to the terminal marked E or the earth symbol or coloured Green or Green/Yellow. Connect the Brown wire to the terminal marked L or coloured Red. Connect the Blue wire to the terminal marked N or coloured Black. DO NOT connect the Brown (Live) or the Blue (Neutral) wires to the Earth terminal of your 13 amp plug. If the terminals of the plug are unmarked or you are in any doubt, consult a qualified electrician. CAUTION: I

Скачали: 2   Размер: 118 kb   Производитель: Dimplex  
Категория: Вентиляторы
@name

The heating elements will not function until the fan is operating. The switches marked ‘I‘ and ‘II’ control the heating elements. The switch marked ‘I’ controls the 800W element. The switch marked ‘II’ controls the 1600W element. When both switches are ON 2400W heat output is available. Operation of Thermostat 1. The heater incorporates a variable thermostat which is controlled by a knob situated on the top right hand side of the front panel. The knob is marked *, 1 - 6, MAX, representing a temp

Скачали: 2   Размер: 118 kb   Производитель: Dimplex  
Категория: Вентиляторы
@name

Safety Warnings • DO NOT COVER OR OBSTRUCT the air inlet or outlet grille. • ENSURE THE APPLIANCE IS EARTHED. Do Not place heater immediately below a socket outlet. If the appliance is covered, there is a risk of fire. Do not use this heater with young children unattended. Do not use this heater in areas where excessive dust exists. Do not touch or obstruct the grille areas when the heater is in operation. Introduction This heater has been designed for fitting in the space behind the plinth of f

Скачали: 0   Размер: 196 kb   Производитель: Dimplex  
Категория: Вентиляторы
@name

The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm. The power supply cable should be routed from the plinth space to the connection box, ensuring that the cable is left with enough slack to allow removal of the appliance for maintenance. The cable must be protected from any sharp edges. 3. Fitting the Rear Support Bracket The heater is supplied with a rear support bracket. Fit to the back of the appliance with the two scre

Скачали: 5   Размер: 196 kb   Производитель: Dimplex  
Категория: Вентиляторы
@name

It is recommended that the heater is not installed under cupboards used for storing perishable goods. It can be accommodated in plinths with a minimum height of 12Omm, and is suitable for cupboards of 500mm width and above. Installation The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE wiring regulations. Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring. T

Скачали: 6   Размер: 1 mb   Производитель: Dimplex  
Категория: Вентиляторы
@name

If 220-240V ~3P Delta supply is to be used a 4 Pin Plug is required (as denoted by * above). The Supply Cable is specifically chosen for each CFP heater and should only be replaced by a similar cable supplied by the manufacturer. See Fig. 4 for CFP Wiring Diagram. (References are listed below) A -Heat 1 Contactor B -Heat 2 Contactor C -Thermal Safety Cut-out Circuit D -Star / Delta Connector Blocks E -Heating Elements F -Mains Lead & Plug G -Earth H -Heat / Fan Selection Switch I -Thermostat T -

Скачали: 7   Размер: 1 mb   Производитель: Dimplex  
Категория: Вентиляторы
@name

1000mm MIN. 380 - 415V 3PN + E H I C G 1L1 3L2 5L3 13NO A1 2T1 4T2 6T3 14NO A2 2T1 4T2 6T3 14NO A2 1L1 3L2 5L3 13NO A1 A B E D M TM F T Dimplex Industrial Fan Heater Models : CFP60, CFP90 & CFP120 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Electrical IMPORTANT SAFETY ADVICE DO NOT COVER OR OBSTRUCT the air inlet or outlet grille. IMPORTANT – Disconnect from the mains supply before carrying out maintenance work. THIS HEATER MUST BE EARTHED Keep combustible mater

Скачали: 6   Размер: 1 mb   Производитель: Dimplex  
Категория: Вентиляторы
@name

Remove the control moulding and top panel. 3. Change over the links on the Star / Delta Terminal Block to resemble Fig. 5a. 4. Remove the blue neutral wire from ‘N’ and connect into ‘L3’ in the Mains In Terminal block. 5. Replace the control moulding and top panel. Attention: If using an extension cable, ensure that it complies with local electrical regulations and is suitable for the loads shown above. Operation The heat output from this heater is regulated using the rotating wheels shown in Fi

Скачали: 4   Размер: 2 mb   Производитель: Dimplex  
Категория: Вентиляторы
@name

Wall Mounting Remove the wall mounting bracket from the back of the heater and using it as a guide (see Fig. 2) mark off the hole positions on a suitable wall (a minimum height of 2 meters is required from the floor level to the bottom of the bracket). Solid brick or concrete block walls must be drilled and plugged. Fix the wall mounting bracket to the wall and assemble the heater to the extension tube using a bolt and wing nut fitted into hole 1 shown in Fig. 3a. Rotate the heater as shown in F