When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet. WARNING -TOREDUCETHERISKOFFIREORELECTRIC SHOCK, do not use this fan with any solid-state speed control device. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before

Скачали: 5   Размер: 473 kb   Производитель: Faber  
Категория: Вентиляторы
@name@name

In a ducted application, this rangehood can be vented through the wall or ceiling. To vent through a wall, a 90° elbow is used. When installed ductless, the rangehood vents out of grates on the sides of the chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer. WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILLBE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS. FIGURE 1RANGEHOOD ASSEMBLY PLAN THE INSTALLATION The P

Скачали: 5   Размер: 543 kb   Производитель: Faber  
Категория: Вентиляторы
@name@name

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible. 45. Elbow 3.0 feet 90. Elbow 5.0 feet 90. Flat Elbow 12.0 feet Wall Cap0.0 feet FIGURE 2 9 Feet Straight Duct 9.0 feet 2 - 90. Elbows 10.0 feet Wall Cap 0.0 feet Total System 19.0 feet FIGURE 3 Version 03/08- Page 5 INS

Скачали: 0   Размер: 264 kb   Производитель: Faber  
Категория: Вентиляторы
@name

The recommended height to install this hood off the cooktop is a minimum of 24" and a maximum of 30" for maximum effectiveness. Also consult the cooktop manufacturer's recommendation. Pre-Planning Your Ductwork - Important: Consult the installation instructions before you begin installing this rangehood. Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6" round duct. Count 45° angles as 3 feet, 90° elbow

Скачали: 2   Размер: 264 kb   Производитель: Faber  
Категория: Вентиляторы
@name

Some ductwork is required to exhaust the unit out of the cabinet. CFM Reducer Kit cfmred For use in make up air environments where an under 300 cfm hood is required. This kit reduces the ducting to 5" round and reduces the cfm to under 300 FABER For a streamlined look in the kitchen, the Cristal HC is your integrated solution. The Cristal HC has a sleek pull-out visor which slides in, flush with your cabinets, neatly tucking the hood away. For total integration, the front strip can be replac

Скачали: 1   Размер: 484 kb   Производитель: Faber  
Категория: Вентиляторы
@name@name

FIGURES 1 and 2 show vertical and horizontal installations for this unit. FIGURE 3 shows recirculating installation. TheMagnumrequires6"roundductwork. Toensure that the blower performs to its highest possible capacity, ductwork should be as short and straight as possilbe. WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS. CALCULATE THE DUCTRUN LENGTH The ductrun should not exceed 35 equivalent feet if d

Скачали: 4   Размер: 181 kb   Производитель: Faber  
Категория: Вентиляторы
@name@name

The ductrun should not exceed 35 feet if ducted with the required minimum of 6" round duct. Calculate the length of the ductwork by adding the equivalent feet in FIGURE A for each piece of duct in the system An example is given in FIGURE B. 45° Elbow 3.0 feet 90° Elbow 5.0 feet 90° Flat Elbow 12.0 feet Wall Cap 0.0 feet FIGURE A 9 Feet Straight Duct 9.0 feet 2 - 90° Elbows 10.0 feet Wall Cap 0.0 feet Total System 19.0 feet FIGURE B For best results, use no more than three 90° elbows. Make sure t

Скачали: 4   Размер: 231 kb   Производитель: Faber  
Категория: Вентиляторы
@name

box 435 • Wayland, MA 01778 • tel: (508) 358-5353 • fax: (508) 358-5730 • e-mail: info@faberonline.com • Dimensional Diagrams Internal Blower Model h- 30" or 36" 1 1/2” 26 1/8" 2 1/8" Remote Blower Model 30" or 36" 1 1/2" 9" diameter A black plastic duct collar plate (provided with the remote blower) attaches to the front of the downdraft plenun over this 9” hole. The 10” (25.4 cm) round duct system attaches to this duct collar plate. 26 1/8" 2 1/8" Ductwork Cutout Dimensions For

Скачали: 5   Размер: 231 kb   Производитель: Faber  
Категория: Вентиляторы
@name

The 10” (25.4 cm) round duct system attaches to this duct collar plate. 26 1/8" 2 1/8" Ductwork Cutout Dimensions For Internal Blower Model Only! Countertop Cutout Dimensions For Both Internal and Remote Models WARNING! Product specifications are subject to change without notification. Consult the installation instructions for Rev. 07/11 both the remote blower and the ventilation system before you begin installing this rangehood.

Скачали: 4   Размер: 231 kb   Производитель: Faber  
Категория: Вентиляторы
@name

The 10” (25.4 cm) round duct system attaches to this duct collar plate. 26 1/8" 2 1/8" Ductwork Cutout Dimensions For Internal Blower Model Only! Countertop Cutout Dimensions For Both Internal and Remote Models WARNING! Product specifications are subject to change without notification. Consult the installation instructions for Rev. 07/11 both the remote blower and the ventilation system before you begin installing this rangehood.