Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Garland, модель GIU 2.5 (BH/BA 2500)

Производитель: Garland
Размер: 2.53 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The limit values stated in this manual must not be exceeded. SECTION 2 – TECHNICAL INFORMATION Model BH/BA (Counter models) 120 V/1 Ph 208 V/1 Ph 240 V/1 Ph Wattage kW 1.5/1.8 kW 2.5/3.5 kW 2.5/3.5 kW Current A 12.5/15 12/14.5/17 10/12.5/14.5 Power factor Cos . >0.95 >0.95 >0.95 Discharge rate mA 4 4 4 . Coil mm 190 (7.5”) 190 (7.5”) 190 (7.5”) Model BH/IN (Counter Models) 208 V/1 Ph 240 V/1 Ph Wattage kW 2.5 kW 2.5 kW Current A 12 10 Power factor Cos . >0.95 >0.95 Discharge rate mA 4 4 . Coil mm 190 (7.5”) 190 (7.5”) Model SH/BA (Counter Models) 208 V/1 Ph 240 V/1 Ph 208 V/3 Ph Wattage kW 3.5 kW 3.5 kW 5 kW Current A max. 16 14.5 max. 16 Power factor Cos . >0.95 >0.95 >0.95 Discharge rate mA 4 4 4 . Coil mm 190 (7.5”) 190 (7.5”) 190 (7.5”) Model SH/IN (Built in Models) 208 V/1 Ph 240 V/1 Ph 208 V/3 Ph Wattage kW 3.5 kW 3.5 kW 5 kW Current A max. 16 14.5 max. 16 Power factor Cos . >0.95 >0.95 >0.95 Discharge rate mA 4 4 4 . Coil mm 190 (7.5”) 190 (7.5”) 190 (7.5”) Model SH/WO (Counter Wok Models) 208 V/1 Ph 240 V/1 Ph 208 V/3 Ph Wattage kW 3.5 kW 3.5 kW 5 kW Current A max. 16 14.5 max. 16 Power factor Cos . >0.95 >0.95 >0.95 Discharge rate mA 4 4 4 . Coil mm 190 (7.5”) 190 (7.5”) 190 (7.5”) Model SH/WO/IN (Built in Wok Models) 208 V/1 Ph 240 V/1 Ph 208 V/3 Ph Wattage kW 3.5 kW 3.5 kW 5 kW Current A max. 16 14.5 max. 16 Power factor Cos . >0.95 >0.95 >0.95 Discharge rate mA 4 4 4 . Coil mm 190 (7.5”) 190 (7.5”) 190 (7.5”) Maximum tolerance of power supply Nominal voltage +6/-10 % Frequency 50/60 Hz Protection class IP X0 Min. diameter of pans Approx. 12 cm ( 4.7” ) Max. ambient temperature: stockage -20°C to 70°C (-4°F to 158°F) Max. ambient temperature: function -5 °C to 40°C (23°F to 104 °F) Max. relative humidity of air: stockage 10 to 90 % Max. relative humidity of air: function 30 to 90 % SECTION 3 – OPERATION Adjusting The Performance Rate The performance rate is adjusted by the potentiometer (control knob). The inductive performance depends on the position of the potentiometer: • Position 1 = minimum power. • Position 9 (resp. Position 12) = maximum power. Temperature Check Induction coil The temperature of the induction coil is checked by a temperature sensor. If the coil is heated over the maximum temperature, the heating process stops. As soon as the coil has cooled down, the Induction unit can be re-started. Turn the position of the control knob to “0” and then to the required power level (See Error Message, Section 6). Power board The temperature of the power board is checked by a temperature sensor. As soon as the heat sink is heated over 70°C (158°F), a cooling fan starts. A heat sink temperature of more than 80°C (176°F) automatically reduces the power in order to keep the induction cooker working under normal conditions. The internal temperature of the unit is supervised as well. The power is reduced by 50% if the temperature reaches 75°C (167°F). As soon as the temperature reaches 90°C (194°F) the unit stops working and shows the ...

Эта инструкция также подходит к моделям:
Варочные панели - GIWOK 3.5 (SH/WO 3500) (2.53 mb)
Варочные панели - GIU 1.5 (BH/BA 1500) (2.53 mb)
Варочные панели - GIU 1.8 (BH/BA 1800) (2.53 mb)
Варочные панели - GIU 2.5 BI (BH/IN 2500) (2.53 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории