Фрагмент инструкции



PHKL_36387: MCA recovery/shutdown patch

PHKL_36332: Cumulative GIO patch

PHCO_36371: PCI OL* DLKM and Chassis Delete
These patches and other required patches are delivered in the FEATURE11i patch bundle
on the HP-UX 11i v3 (B.11.31) OEUR media for September 2007. You may also check
availability of the patch at the HP IT Resource Center site: http://itrc.hp.com

crashconf displays incorrect size for dump devices
FibrChanl-01 now supports dump devices that are greater than 2TB in size. However,
crashconf displays an incorrect size for dump devices that are greater than 4TB.
Corrective action: Install patch PHCO_36550 to fix this problem. This patch is delivered in
the HWEnable11i patch bundle on the HP-UX 11i v3 (B.11.31) OEUR media for December
2007. You may also check availability of the patch at the HP IT Resource Center site: http://
itrc.hpc.om


Critical Resource Analysis (CRA) may unexpectedly fail
Critical Resource Analysis (CRA) may unexpectedly fail during Online Replacement (OLR),
Online Deletion (OLD), or during dynamic unload of the fcd driver module, causing a core
dump.
OLR occurs when performing a replacement operation with the olrad command, PCI attention
button, or the System Management Homepage (SMH) on systems with this OLR feature.
OLD occurs when performing a delete operation with the olrad command, or with the Systems
Management Homepage (SMH) on systems with this OLD feature.
A dynamic module unload can occur with kcmodule, swinstall, or swremove commands.
If the CRA fails in this way during a swinstall or swremove operation, the system will
automatically reboot to complete the requested operation. If the CRA fails during a kcmodule
fcd=unused operation, the unload action will not occur until the system is manually rebooted.
Corrective action: Install patch PHCO_36356 to fix this problem. This patch is delivered in
the HWEnable11i patch bundle on the HP-UX 11i v3 (B.11.31) OEUR media for December
2007. You may also check availability of the patch at the HP IT Resource Center site: http://
itresourcecenter.hp.com


Update to Software Distributor is required
If the updated or patched Software Distributor is not in place, a necessary reboot might not
be performed during installation of the I/O drivers with DLKM functionality, which includes
the FibrChanl-01 product.
Corrective action: On systems prior to the HP-UX 11i v3 December 2007 OEUR, you must
install Software Distributor patch PHCO_36530, or install the B.11.31.0709.308 or later
revision of the Software Distributor product from http://docs.hp.com/en/SD

EFI SEARCH causes boot to fail on rx7640, rx8640, and sx2000 Superdome server systems
Running the SEARCH command at the EFI shell on rx7640, rx8640, and HP Integrity
Superdome/SX2000 server systems can cause the system to fail to boot through a Fibre
Channel HBA. rx7640 systems have a built-in SEARCH of slot 7. Affected 2Gb Fibre Channel
HBAs are: A6826A, A9782A, A9784A, and AB465A with EFI driver version 1.47 or earlier.
Affected 4Gb Fibre Channel HBAs are: AB378A and AB379A with EFI driver version 1.01.
The boot will fail with a message similar to the following:
Load of HP-UX Primary Boot: 1.0.1/1/0/4/0.8.0.255.0.6.0
failed: Not Found