Do not disturb sensor scanning procedure (wait until water flow stops and LED switches off) Replace electronics module (See “Replacement Parts”) Change mode or reset sensor (See “Care and Maintenance”) Check external water pressure Provide pressure between 20 - 125 psi Replace solenoid valve (See “Replacement Parts”) Replace electronics module (See “Replacement Parts”) Water runs continuously Water fl ows although shut-off screw is inoperable removed Water drops on infrared window Infrared windo

Скачали: 0   Размер: 2 mb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for another four (4) additional water pulses. 3 Remove hand. Result: Scrub Mode is now activated for 180 seconds. F - Sensor Range Adjustment The detection distance of the sensor can be adjusted between approximately 4 - 11 inches from the infrared window. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 R

Скачали: 0   Размер: 2 mb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

. . . . . . . . . . . . . . . . . . . . . . . . . .9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 10 Care and Maintenance . . . . . . . . . . . . . . . . . 12 Multi-Faucet Transformer Wiring . . . . . . . . . 14 IMPORTANT! Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Se

Скачали: 0   Размер: 2 mb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

Possible solenoid contamination could occur and will void any warranty. Mounting of Lavatory and Gooseneck Faucet Prerequisites • Supply valve is installed • Water supply lines are fl ushed properly • For AC faucets, power outlet is installed It is not necessary to unscrew the connection between braided hose and housing to install the product. Do not remove protective covering from sensor until starting up faucet operation. Do not tighten locknut before step 4 is completed. 1 Mount cover plate i

Скачали: 9   Размер: 2 mb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

The hardware, firmware, or software described in this document is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNEW OF, OR SHOULD HAVE KNOWN OF, THE POSSIBILITY OF SUCH DAMAGES. Enterasys Networks, Inc. 50

Скачали: 2   Размер: 773 kb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

. . . . . . . . . . . . . . . .2 Model TDB3104 Washfountain Dimensions . . . . 3 Model WF3204 Washfountain Dimensions . . . . . .4 Washfountain Rough-Ins . . . . . . . . . . . . . . . . . .5-7 Drain Installation . . . . . . . . . . . . . . . . . . . . . . . . . .8 Bowl/Pedestal Mounting and Assembly . . . . . . . .9 Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10 Air Valve Installation (A/O drains) . . . . . . . . .11-12 Air Valve Installation (B/H drains) . . . . . . . . .13

Скачали: 8   Размер: 773 kb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

For more than three washfountains, pipe sizes should be increased proportionately. -Supplies from below or through wall - Vented through ceiling off trap inside pedestal Type O Drain -Supplies from above - Vented from below or through wall off drain (mm) Figure 2d NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increased proportionately. Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 T

Скачали: 14   Размер: 643 kb   Производитель: Bradley Smoker  
Категория: Сантехника
@name@name@name

2 Wall Shower Components .................... 2 Wall Shower Dimensions ..................... 3 Step 1: Rough-In Piping ...................... 3 Step 2: Install Shower ........................ 3 Vertical Shroud Installation ................... 4 Horizontal Shroud Installation ................4 Table des Matieres Fournitures requises ......................... 5 Hauteurs de douche conseillees .............. 5 Elements de la douche ......................5 Dimensions de la douche ....................

Скачали: 1   Размер: 609 kb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

Read this entire installation manual to ensure proper installation, then file theseinstructions with the owner or maintenance department. Flush all the water supply lines before making connections, then make sure the watersupply is turned off before beginning installation. Do not use pipe dope on faucet and supply connections. Possible solenoid contaminationcould occur and will void any warranty. Teflon tape is the recommended sealant. The installation site should have access to an electrical bo

Скачали: 2   Размер: 562 kb   Производитель: Bradley Smoker  
Категория: Сантехника
@name

O.D. washers to mount main frame and bowl to wall (minimum pull-out rating of 1,000 lbs.) • (2) #10 wall anchors (for optional mixing valve/bracket mounting) • 1/2" NPT hot/cold or tempered supply piping • 1-1/2" NPT drain piping • OPTIONAL: 110 volt GFCI protected electrical outlet for 100–120 VAC plug-in transformer (for Bradley Faucets) • OPTIONAL: 240/208 or 277 volts for electric tankless water heater Installation FL-1H, FL-1L Cleaning and Maintenance for Terreon® Material Description: Terr