Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Bradley Smoker, модель Terreon TDB3104

Производитель: Bradley Smoker
Размер: 773.3 kb
Название файла: wf1470.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . . . . . . . . .2 Model TDB3104 Washfountain Dimensions . . . . 3 Model WF3204 Washfountain Dimensions . . . . . .4 Washfountain Rough-Ins . . . . . . . . . . . . . . . . . .5-7 Drain Installation . . . . . . . . . . . . . . . . . . . . . . . . . .8 Bowl/Pedestal Mounting and Assembly . . . . . . . .9 Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10 Air Valve Installation (A/O drains) . . . . . . . . .11-12 Air Valve Installation (B/H drains) . . . . . . . . .13-14 Valve and Tubing Connections . . . . . . . . . . . .15-17 Vernatherm Adjustment Procedure . . . . . . . . . . . .18 Terreon® Cleaning/Maintenance . . . . . . . . . . . . .19 Gel-Coated Fiberglass Cleaning/Maintenance . . .19 Stainless Steel Cleaning/Maintenance . . . . . . . . .20 Soap Dispensing Valve Repair Parts . . . . . . . . . .21 Soap Recommendations and Maintenance . . . . . .23 Sprayhead Troubleshooting/Repair Parts . . . . . . 24 Actuator Module Assembly Components . . . . . .25 Metering Air Valve Maintenance . . . . . . . . . .25-27 Vernatherm™ Mixing Valve Maintenance . . .28-29 Cleaning the Strainer . . . . . . . . . . . . . . . . . . . .28-29 P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Pre-Installation Information IMPORTANT: Read this entire installation manual to ensure proper installation. IMPORTANT: Flush all the water supply lines before making connections. IMPORTANT: Main water supply to the unit should be ON at all times. IMPORTANT: This installation manual and parts list should be filed by the owner’smaintenance department. Cylindrical air valve The air valve pushbutton allows each user to activate an air metering valve (starting the flow of water) by pushing and releasing the pushbutton. The air metering valve is factory-preset to run for 10 seconds and can be adjusted to run from 5-60 seconds. Supplies required for installation: • (4) lag bolts, screws or other fasteners to anchor washfountain pedestal • 1" hot and cold water supply lines and fittings (refer to rough-ins on pages 6-7) • Reducing fittings and 1/2" nom. copper tubing supply lines for types with supplies from above • Standard P-trap (refer to rough-ins on pages 6-8) (vented trap supplied by Bradley when required) • 2" drain lines and fittings (refer to rough-ins on pages 6-7) • Teflon tape or pipe dope • 1-1/2" vent or tie pipe on fixtures vented through washfountain column (see page 8 for lengths required) Terreon® Semi-circular Washfountain Warranty Product warranties may be found under “Product Information” on our website at 2/8/07 Bradley Corporation • 215-1470 Rev. H; EN 06-915 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Semi-Circular Washfountain Dimensions Model TDB3104 34" (864) 40" (1016) 43-3/4" (1111) 32-1/4" (819) 5-1/4" (133) 6" (152) 47-1/4" (1200) 55-3/4" (1416) 64" (1626) WITH SOAP 23-1/2" (597) 27" (686) 22-3/4" (577) 15" (381 ADJUST TO TOWEL DISPENSER MOUNTING HOLES Optional equipment may not comply with all ADA dimensional guidelines 54" Semi-circular - side view 55-1/2" (1410) WITHOUT SOAP Figure 1a Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Semi-Circular Washfountain Dimensions (juvenile height) *34" (864) *39-1/8" (994) 32-1/4" (819) 5-1/4" (133) 6" (152) *42-5/8" (1084) *51-1/4" (1301) *59-1/2" (1511) WITH SOAP *51" (1295) WITHOUT SOAP *23-1/2" (597) *30" (762) 22-3/4" (577) 15" (381 * ADD 2" (51) FOR TAS HEIGHT UNIT ADJUST TO TOWEL DISPENSER MOUNTING HOLES Model TDB3104 54" Semi-circular - side view Figure 1b Optional equipment may not comply with all ADA dimensional guidelines 54" Semi-circular - rear view pedestal access Figure 1c 17-1/2" (444) 12-1/2" (318) *3-1/2" (89) 2/8/07 Bradley Corporation • 215-1470 Rev. H; EN 06-915 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Semi-Circular Washfountain Dimensions 34" (864) 41" (1041) 43-3/4" (1111) 32-1/4" (819) 5-1/4" (133) 6" (152) 47-1/4" (1200) 55-3/4" (1416) 64" (1626) WITH SOAP 23-1/2" (597) 22-3/4" (577) 15" (381 ADJUST TO TOWEL DISPENSER MOUNTING HOLES Model WF3204 is not ADA compliant Model WF3204 54" Semi-circular - side view 55-1/2" (1410) WITHOUT SOAP Figure 1d Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Rough-In Specifications Type A Drain - Vent from below or through wall off-drain (mm) Figure 2a - Supplies from below or through wall NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increas...

Эта инструкция также подходит к моделям:
Сантехника - Terreon WF3204 (773.3 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории