Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Bradley Smoker, модель AERADA 1000 Series S53-329

Производитель: Bradley Smoker
Размер: 2.24 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not disturb sensor scanning procedure (wait until water flow stops and LED switches off) Replace electronics module (See “Replacement Parts”) Change mode or reset sensor (See “Care and Maintenance”) Check external water pressure Provide pressure between 20 - 125 psi Replace solenoid valve (See “Replacement Parts”) Replace electronics module (See “Replacement Parts”) Water runs continuously Water fl ows although shut-off screw is inoperable removed Water drops on infrared window Infrared window is dirty or scratched Input line pressure fluctuates Connections between housing and braided hoses are loose Connection between braided hose and inlet supply are loose Connection between valve body and solenoid valve is loose Faucet drips, solenoid valve does not close properly No, or too little hot or cold water. Supply valves are not fully opened Inlet water line filter is dirty or blocked Braided hose is kinked Backflow preventer in faucet inlet is blocked Temperature of hot or cold water supply is too low Hot water temperature not suffi cient Braided hoses are connected improperly (cold to hot and hot to cold) Clean window with smooth cloth Clean window with smooth cloth Install appropriate line pressure regulators Check O-rings Replace O-rings when damaged or missing Check rubber washers Replace washers when damaged or missing Check O-rings Replace O-rings when damaged. Carefully reinstall solenoid valve and do not overtighten. Clean or replace solenoid valve (See “Replacement Parts”) Fully open supply valves Clean or replace filter (See “Care and Maintenance”) Eliminate braided hose kink Unblock backflow preventer Check inlet water temperature or inspect boiler Reverse hot water limiter (See “Care and Maintenance”) Correct the connections Faucet turns on by itself Faucet is leaking water Temperature cannot be adjusted properly Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 Aerada 1000/1100 Series Installation 12 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 CARE AND MAINTENANCE INSTRUCTIONS The following instructions are described in this section: • Activating Cleaning Mode • Replacing Battery • Cleaning or Replacing Inlet Filter • Adjusting Water Temperature (Internal Mixer) • Adjusting Hot Water Limiter (External Mixer) • Cleaning or Replacing Aerator Activating Cleaning Mode In order to set the cleaning mode, the faucet needs to be have been set once into the “Manual Setting” mode. See “Manual Setting” instructions. When cleaning mode is activated, the faucet will be inoperable for 90 seconds. 1 Fully cover sensor with hand, until water fl ow stops. (This takes approximately 5 seconds.) 2 Remove hand. Result: Cleaning Mode is now activated. Replacing Battery A traditional lavatory faucet is shown as an example. These instructions apply to all DC models. Prerequisites • Battery is low (LED is lit) • New 6 V Lithium battery (CR-P2) is required 1 Remove shut-off screw 2 Remove mixer handle (for faucets with external mixer only) 3 Remove housing vertically. 4 Remove used battery from battery holder and recycle. 5 Insert new battery. > LED lights up for 1 second 6 Mount housing vertically. Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 13 7 Install shut-off screw. 8 Install mixer handle (for faucets with external mixer only). Result: The battery is now replaced. Cleaning or Replacing Inlet Filter 1 Close supply valves. 2 Disconnected braided hoses and clean or replace fi lter (for a new fi lter, see “common replacement parts”). 3 Connect braided hose with fi lter to supply valve Cold water > white label Hot water > no label Result: The fi lter is now cleaned or replaced. Adjusting Hot Water Limiter (External Mixer) The proportion of hot water can be switched from approximately 85% to 95% (or reverse) depending upon inlet water pressures and temperatures. The default setting is 85%. WARNING Hot water may burn your skin. Hold hand carefully under water and remove quickly 1 Remove mixer handle. 2 Carefully pull out hot water limiter from handle (using pliers) and reverse by 180°. > Settings of hot water limiter (View from placement in mixer handle) 3 Mount mixer handle. Result: The proportion of hot water is now changed. 180° 85% 95% Aerada 1000/1100 Series Installation Cleaning or Replacing Aerator 1 Remove shut-off screw. 3 Install shut-off screw. 2 Remove aerator with vandal resistant wrench supplied with the faucet. Clean or replace aerator, then reinstall. Result: The aerator is now cleaned or replaced. Multi-Faucet Transformer Installaion AC CONNECTOR BANK INSTALLATION FROM FAUCET ADAPTER WIRE BANK INSTALLATION ADAPTER WIRE (INCL. W/AC FAUCET) 232-009 (1–8 faucets) ADDITIONAL WIRING (IF NEEDED) TO BE SUPPLIED BY CUSTOMER (22 GA min; 50 ft. max. length) Transformer can be used to connect up to 8 faucets. All units must be connected in parallel. 14 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 ...

Эта инструкция также подходит к моделям:
Сантехника - AERADA 1000 Series S53-327 DC (2.24 mb)
Сантехника - AERADA 1000 Series S53-326 AC (2.24 mb)
Сантехника - AERADA 1000 Series S53-328 (2.24 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории