For more than three washfountains, pipe sizes should be increased proportionately. -Supplies from below or through wall - Vented through ceiling off trap inside pedestal Type O Drain -Supplies from above - Vented from below or through wall off drain (mm) Figure 2d NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increased proportionately. Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions Step 1: Installing the drain 1. Rough in supply and drain piping as required for your installation (see pages 6-7 for rough-ins of the optional installations). 2. Assemble the drain to the dimension shown in Figure 3 for the bowl you are installing. NOTE: All piping shown in dotted lines to be supplied by installer. Centerline ofWashfountain Centerline ofWashfountain Centerline ofWashfountain See rough-inson Pages 6-7for dimensions not shown Types B, H Types A, O With Tie Pipe Bracket Option Types A, O 2" NPT Coupling if TiePipe is not required(Supplied by Installer) Vent or Tie Pipe(Supplied by Installer) Vent or Tie Pipe(Supplied by Installer) Vented Trap(111-024) OptionalTie Pipe Bracket (S70-082) 4" (102) 4" (102) B – See Table 1 B – See Table 1 B – See Table 1 4" (102) Figure 3 Table 1 — “B” Trap Dimensions Dim Standard Height Juvenile Height TAS B 23-3/8" (594mm) 22-1/2" (572mm) 24-1/2" (622mm) 2/8/07 Bradley Corporation • 215-1470 Rev. H; EN 06-915 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . Step 2: Bowl/pedestal mounting and assembly 1. Position pedestal at desired location and mark the position of the (2) pedestal wall mounting locations and (2) pedestal floor mounting locations (see Figure 5b). TAS Option: Place TAS spacer on floor over the mounting holes. Place pedestal on top of the spacer. 2. Secure pedestal to wall and floor with suitable fasteners, 1/2" anchors and 1/2" bolts (supplied by installer) (see Figure 5b for floor and wall mounting locations). 3. Using two to three people, carefully lift bowl onto pedestal (see Figure 5b). 4. Position bowl so that threaded rods in bowl mate with slotted holes in pedestal (see Figure 5b). 5. Using 1/4" wing nuts and washers, secure bowl to pedestal, three places (see Figure 5b). CAUTION: BOWL SURFACE IS VERY SMOOTH. APPROXIMATE WEIGHT OF BOWL IS 146 LBS. (model TDB3104), 136 lbs. (model WF3204) or 101 lbs. (TDB3104/JUV). HANDLE WITH CARE! PLACE HANDS HERE WHEN LIFTING BOWL WALL MOUNTING LOCATIONS PLACE HANDS HERE WHEN LIFTING BOWL FLOOR MOUNTING LOCATIONS PEDESTAL DRAIN THREADED ROD (Secured by 1/4" wing nut and washer) Figure 5b Figure 5a DRAIN TOP VIEW FRONT VIEW Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . Step 3: Installing drain spud in bowl NOTE: Seal between drain spud and drain hole with plumber’s putty (supplied by installer). 1. Loosely attach the drain spud to the bowl with the locknut and washer as shown in Figure 6. B Trap Option: Attach B Trap to drain spud. Tie Pipe Option: Attach Tie Pipe Bracket to drain spud. 2. Tighten the spud and lock nut against the bowl. 3. Secure the strainer to drain spud with the screws provided. 4. Connect spud (or B Trap or Tie Pipe Bracket) to drain. STRAINER S45-067 SPUD 112-015 BOWL WASHER 142-068 LOCKNUT 161-021 DRAIN PRE-PACK S45-273 Figure 6 2/8/07 Bradley Corporation • 215-1470 Rev. H; EN 06-915 Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . Step 4a: Air Metering Valve assembly for A drain and O drain units without Tie Pipe option 1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 7). 2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through the support tube and connect to valve tube connector. Make sure the spray holes point away from the wall. 3. Place the upper tie bar (notched at both corners of each end) on top of sprayhead parallel to wall. Connect the longer tie rod to the 4-1/4" tie rod using the coupling nut with hex head set screws. Run the tie rod assembly down through upper tie bar (see Figure 7 inset) and secure from underneath the bowl using lower tie bar (no notches) and hex nut with socket head set screw. SUPPORT TUBE GASKET 125-011 SUPPORT TUBE (STD) S57-005 (TAS) (JUV) S57-006 STD. TIE ROD 176-008A JUV. TIE ROD 176-008 TIE BAR PRE-PACK S45-055 SEMI-CIRC. BOWL PRE-PACK S45-1523 1/2" FLEXIBLE SUPPLY TUBE TIE BAR STANDARD PEDESTAL ASSY. S17-259 TAS PEDESTAL ASSY. S17-345 TOP COVER 107-099 (A) 107-179 (O) ACTUATOR MODULE ASSY. S65-134 RE...
Эта инструкция также подходит к моделям:Сантехника - Terreon TDB3104 (773.3 kb)