Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Stovax, модель SLBV-35NE

Производитель: Stovax
Размер: 2.89 mb
Название файла: Lennox_Superior_SLBV_Installation_Instructions_506009_02.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Closingitwhennotinusewillhelplimitthe amount of outside cold air entering the dwelling. Operate the actuator through several cycles including the closed position. Ensuring proper operation and freedom of movement. Return the actuator arm to the closed position. Left Side of Lower Control Compartment Figure 15 Securing Screw Removed Outside Air Control Lever pulled DOWN (Air Shutter OPEN) Outside Air Control Lever pushed UP (Air Shutter CLOSED) Securing Screw Installed IMPORTANT: Do NOT move Air Control Lever if securing screw is installed (or if not sure it was removed). WARNING do not operate the shutoff lever unless a complete outside com bustion air system has been installed with your appliance. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIOR® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Figure 17 Step 6. Connect the Gas Line All codes require a shut-off valve mounted in the supply line. The orientation of the shutoff valve should face the front. Figure 16 illustrates two methods for connecting the gas supply. A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve. The flex-line method is acceptable in the U.S.A. where local codes permit, however, Canadian requirements vary depending on locality. Installation must be in compliance with local codes. These appliances are equipped with a gas flexline for use in connecting the unit to the gas line. See Figure 16 for flex-line description. The flex-line is rated for both natural and propane gas. A manual shut off valve is also provided with the flex-line. The gas control valve is located in the lower control compartment. Access the valve compartment by removing the lower control compartment panel (see Figure 17) by lifting and pulling the panel forward. The panel is mounted on supporting tabs at the extreme right and left hand sides. Engage the tabs into the reliefs in the panel. The millivolt and electronic control valve has a 3/8" (10 mm) NPT thread inlet port. Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). It is recommended to seal around the gas line to prevent cold air leakage. Gas line connection may be performed largely outside of the confines of the control compartment and without having to enter the firebox behind the glass. Proceed as follows: Acquire the shut-off valve and gas flex-line and pull the assembly forward out of the compartment. Separate the shut-off valve from the gas flex-line. Determine the length of pipe needed to route the gas line from the last fitting (shown in Figure 9) to a point within the control compartment that will allow the shut-off valve to be easily attached by hand to the gas flex-line. Using pipe-dressing materials appropriate for the gas type, securely affix the shut-off valve to this determined pipe length at a convenient location outside of the ...

Эта инструкция также подходит к моделям:
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории