It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. Check local codes for additional requirements. If the fireplace is being installed on a cement slab in cold climates, a sheet of plywood or other raised, insulated platform can be placed underneath to prevent cold transfer to the fireplace and into the room. It also may help to sheetrock the inside surfaces and/or tape for maximum air tightness. LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies (Figure 3). En raison des temperatures elevees, l’appareil devrait etre installe dans un endroit ou il y a peu de circulation et loin du mobilier et des tentures (Figure 3). The location should also be free of electrical, plumbing or other heating/air conditioning ducting. These appliances are equipped with an integral combustion air door and actuator arm. Combustion air kits are optional and must be installed before removing the securing screw allowing the movement of the combustion air actuator arm (see Step 5 on Page 14). Be aware that this is a heat-producing appliance. Objects placed above the unit are exposed to elevated temperatures. The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or woodbarriercoveringtheentirebottomsurface must be used. These appliances may be used for bedroom installationsintheUnitedStatesandarelisted accordingly. These units may not be installed in bedrooms in Canada. Note: When the unit is installed with one side flush with a wall, see Figure 5 on Page 7. Figure 3: Typical Locations NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. - - . SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUSTIBLES Appliance and Vent Clearances The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 6), with the following exception: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (see Figure 5). MINIMUM CLEARANCES -Inches (millimeters) Back 0 (0) to Standoffs or dimples Sides 0 (0) to Standoffs or dimples** Top 3 in (76 mm) floor 0 (0) from Bottom of Unit to Ceiling 64 in (1626 mm) Vent 1 in (25.4 mm) SERVICE CLEARANCES front 3 ft (0.9 m) Table 6 **Note: See Step 1 on Page 8 for clearance requirements to the ...

Эта инструкция также подходит к моделям:
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)
Камины - SLBV-35NE (2.89 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории