Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Vermont Casting, модель RADVTCEB

Производитель: Vermont Casting
Размер: 4.03 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


(Fig. 14) CAUTION: To prevent valve tubing from being crushed or damaged, do not rest valve or ignitor on wooden pallet. Washer Hex Head BoltST721 Fig. 14 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward. 4. Have your assistant attach one leg using the hardware described. 5. Move the pallet to allow access to the other front leg hole. Attach remaining leg. 6. Remove pallet and allow stove to gently rest on all four legs. 7. Adjust leg levelers to compensate for irregularities in the hearth. NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening. 15 Radiance Direct Vent Gas Heater 20012697 ST347a JUV FK28 rheostat install 9/21/00 Rheostat Retaining Collar Rheostat Knob ST347a Fig. 18 Attach the fan rheostat. Rheostat Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you are not installing a Fan Kit, go to Page 16, Venting System Assembly. 1. The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 15) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve coverplate. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109.. The Rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm that the fan spins freely. ST147 RDV40 remove rear shroud 10/99 Fig. 16 Remove rear shroud. ST147 ST473 Fan parts #2767 FK26 9/29/00 Not Used On Radiance Snapstat Bracket Snapstat/ Extension Assembly Rheostat Assembly ST473 Blower Assembly Fig. 15 Fan kit components. Not Used On RF Models Not Used On RF Models Connect to PC board on RF models only WARNING This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. 2. Remove the rear shroud panel (Fig. 17) and fasten the blower assembly to the firebox back with the two bolts provided. (Fig. 17) NOTE: Steps 3 and 4 do not apply to RADVTC series Comfort Control models. On these models, after attaching blower assembly to the firebox, run the spliced female leads to the front of the stove and attach to back of Honeywell valve. (Page 33, Fig. 59) 3. Attach the snapstat assembly to the snapstat bracket with two sheet-metal screws. Attach the snapstat bracket to the side shield. (Fig. 17) 4. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 18) ST149 rdv attach fan assy 10/99 Side Shield Snapstat Bolts ST149 Fig. 17 Attach blower assembly and snapstat. • Remove retaining nut from shaft of rheostat. (if preinstalled) • Insert the rheostat through the hole in the back of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket. • Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not overtighten. • Attach the control knob to the rheostat shaft. • Use the wire tie to secure the fan and rheostat wire harnesses together. Radiance Direct Vent Gas Heater Venting System Assembly General Information The Radiance is approved for installation only with the vent components listed on Pages 12 and 13. Follow the vent component instructions exactly. For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Install the Vent Adapter Pipe (CFM Corporation Vent Components) 1. Attach Inner Starter Pipe, (found in the Parts Bag), to the next section of inner pipe. • Run a bead of sealant about 1/2” from the upper end of the Inner starter pipe and join the two sections together. • Drill three pilot holes into the Inner Starter and secure the assembly with three sheet metal screws. (Fig. 19) CEMENTFirst Section of Vent Pipe 1/4”-20 x 1/2” Phillips Screw 4” Inner Starter Pipe ST211 Fig. 19 Connect the inner starter with the next section of in- ner vent pipe. 2. Dry fit the Inner Pipe assembly to the stove for the purpose of determining the center line of the pipe on the wall. • Side Wall Terminations: Dry fit the outer elbow with the vertical outer vent and confirm the centerline alignment with the wall thimble opening. 3. Attach the Inner Vent Assembly to the stove. • Run a bead of sealant around the bottom end of the starter pipe and attach the assembly to the stove using three 1/4-20 x 3/8” Phillips screws provided in the parts bag. (Fig. 20) CEMENT ST648a Fig. 20 Attach...

Эта инструкция также подходит к моделям:
Камины - RADVTSG (4.03 mb)
Камины - RADVTVG (4.03 mb)
Камины - RAD- VTBB (4.03 mb)
Камины - RADVTBD (4.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории