Войти:
Оценок - 3, средний балл: 3 ( )

Инструкция по эксплуатации Vermont Casting, модель RADVTCVG

Производитель: Vermont Casting
Размер: 4.03 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


1 In accordance with the current CSA-B149 Installation Codes 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings ‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances. 2. The special venting system used on Direct Vent Stoves are certified as part of the appliance, with clearances tested and approved by the list- ing agency. 3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Fig. 11 Vent termination clearances. Radiance Direct Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Outside Corner Alcove Applications* G = Combustible 6" (152 mm) Noncombustible 2" (51 mm) F = Combustible 6" (152 mm) Noncombustible 2" (51 mm) G Balcony - with no side wall M = Combustible & Noncombustible 12" (305 mm) M Balcony - with perpendicular side wall M = 24" (610 mm) P = 20” (508 mm) M FV V Combustible & Noncombustible V V P C D C E V E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. O No. of Caps DMin. CMax. 1 3’ (914 mm) 2 x DActual 2 6’ (1.8 m) 1 x DActual 3 9’ (2.7 m) 2/3 x DActual 4 12’ (3.7 m) 1/2 x DActual DMin. = # of Termination caps x 3 CMax. = (2 / # termination caps) x DActual *NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Fig. 12 Termination clearances. Radiance Direct Vent Gas Heater Venting Requirements and Options Approved Vent System Components The Radiance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified on this page. These parts are available from DuraVent Corporation, Selkirk Corporation or your Vermont Castings Dealer. See Figure 4 for dimensions relevant to the standard minimum-vent kits. Simpson DuraVent Components Phone: 1-800-835-4429, Fax: 1-707-446-4740 Minimum Horizontal Vent Kit 2792 Starter Pipe Assembly (incl. inner & outer sections) 2768* 90° Elbow, Blk. 46DVA-E90B* 45° Elbow, Gal. 46DVA-E45 6” Straight, Blk. 46DVA-06B* 9” Straight, Blk. 46DVA-09B 11” - 14...” Adjustable Straight Section 46DVA-08AB 12” Straight 46DVA-12 24” Straight 46DVA-24B* 36” Straight 46DVA-36B 48” Straight 46DVA-48 Horizontal Vent Cap 46DVA-HC* Wall Plate 46DVA-DC Vinyl Siding Shield 46DVA-VSS Snorkel Termination - 14” 46DVA-SNK14 Snorkel Termination - 36” 46DVA-SNK30 Wall Strap 46DVA-WS Cathedral Ceiling Support Box 46DVA-CS Storm Collar 46DVA-SC Firestop Spacer 46DVA-FS Flashing 0/12 - 6/12 46DVA-F6 Flashing 6/12 - 12/12 46DVA-F12 Steel Chimney Conversion Kit Kit A (6...” - 8...”) 46DVA-KCA Kit B (6...” - 10...”) 46DVA-KCB Kit C (6...” - 13”) 46DVA-KCC Masonry Chimney Conversion Kit 46DVA-KMC Vertical Termination Cap (High Wind) 46DVA-VCH Vertical Termination Cap (Low Profile) 46DVA-VC *Included in Minimum Horizontal Vent Kit #2792 All DuraVent Straight vent pipe sections have a net length 1...” (37mm) less than the nominal dimension; i.e., a 6” (152mm) Straight pipe section has an effective length of 4...” (115mm). Selkirk Corporation Vent Components 1301 W. President George Bush Highway Ste. 330 Richardson, TX 75080 Phone: 1-800-992-8368, Fax: 1-877-393-4145 Appliance Adapter 4DT-AAV 90° Elbow, Blk. 4DT-EL90B 45° Elbow, Blk. 4DT-EL45B 6” Straight, Blk. 4DT-06B 9” Straight, Blk. 4DT-09B 4” - 10” Adjustable Straight Section, Blk. 4DT-AJ12 12” Straight, Blk. 4DT-12B 18” Straight, Blk. 4DT-18B 24” Straight, Blk. 4DT-24B 36” Straight, Blk. 4DT-36B 48” Straight, Blk. 4DT-48B Horizontal Vent Cap 4DT-HC Wall Plate 4DT-WT Vinyl Siding Shield 4DT-VS Snorkel Termination - 14” 4DT-ST14 Snorkel Termination - 36” 4DT-ST36 Wall Strap 4DT-WS/B Cathedral Ceiling Support Box 4DT-CCS Storm Collar 4DT-SC Firestop Spacer 4DT-FS Flashing 0/12 - 6/12 4DT-AF6 Flashing 6/12 - 12/12 4DT-AF12 Steel Chimney Horizontal Kit A 4DT-HKA Horizontal Kit B 4DT-HKB Vertical Kit 4DT-VKC Masonry Chimney Kit 4DT-MCK Radiance Direct Vent Gas Heater Vertical Termination Cap 4DT-VC and all of the other Vertical Termination parts. Twist Lock 12” Straight Pipe (CG) 7TFSDVP12 CFM Vent Components (1) 12” Non-adjustable Pipe The ...

Эта инструкция также подходит к моделям:
Камины - RADVTSG (4.03 mb)
Камины - RADVTVG (4.03 mb)
Камины - RAD- VTBB (4.03 mb)
Камины - RADVTBD (4.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории