Инструкция по эксплуатации Vermont Casting, модель RADVTCBS

Производитель: Vermont Casting
Размер: 4.03 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Orient the vertical seam to the rear, and insert the crimped end of the outer pipe into the flue collar. Fasten with three sheet metal screws provided. (Fig. 23) CEMENT ST649 Inner Adpater Pipe 1/4-20 x 3/8” Phil- lips Screws Fig. 22 Simpson DuraVent - install inner adpater pipe. ST649 Inner Adpater Pipe 1/4-20 x 3/8” Phil- lips Screws Fig. 22 Simpson DuraVent - install inner adpater pipe. Radiance Direct Vent Gas Heater minimum of 1...” over the flue outlet. The outside of the Direct-Temp Length will fit inside the flue outlet Secure with a minimum of two #8 x 1/4” sheet metal screws and seal with hi-temp silicone. For units factory equipped with appliance adapters from other brands of Direct Vent systems, it is permissible to simply slide a length of DT pipe over the appliance adapter. Secure with a minimum of two #8 x 1/4” sheet metal screws and seal with hi-temp silicone. Side Wall Termination Assembly 1. Locate the vent opening on the wall. Refer to Page 6, Figure 5, to determine the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materials, cut the opening to the size shown in Figure 24. Combustible wall openings must be framed as shown in Figure 24. Install Vent Adapter Pipe (Selkirk Corporation Vent Components) The appliance adapter (AA) adapts DIRECT-TEMP to most direct vent appliances incorporating outlet collars configured to receive most common 4” (ID) by 6...” Fig. 24 Locate vent opening. (OD) or 5” (ID) by 8” (OD) “Twist Lock” style, direct vent ST651 Fig. 23 Simpson Dura-Vent - install outer adapter pipe. 9...” (240mm) 7...” 9...” (240mm) Framing Detail Combustible Wall Noncombustible Wall VO584-100 CFM System DuraVent System 10” (254mm) 10” (254mm) NOTE: When Dura-Vent firestop is installed, leave air space on top side of cut out. systems. The adapter incorporates two indentations on the outer wall of the inlet end, which are designed to “Twist Lock” into place upon attachment to the appliance outlet. Align the adapter indentations with the entry slots of the appliance outlet and slide together. Turn the adapter clockwise approximately one-quarter turn to lock in place. The outlet end of the adapter is standard DIRECTTEMP construction. For connection of Direct-Temp to units with 4” x 7” flue outlets, the following methods have been approved: • Install the Universal/Napoleon Appliance Adapter 4DT-AAN. • Connect a standard Direct-Temp pipe length (do not use an adjustable length in this application) a 2. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 25) NOTE: The wall sleeve is required in combustible walls only. 3. Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 25) For DuraVent pipe only: Install vent pipe by aligning the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before attaching the horizontal run to the elbow. Fasten wall plate to wall. 20012697 17 Radiance Direct Vent Gas Heater 12” (305mm) Max. Length Sleeve #8 Sheet Metal Screws Firestop ZCS103 Fig. 25 Assemble the wall sleeve and firestop. 4. For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from the adapter pipe to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 26) use a hacksaw or tin snips to trim the pipe as needed. RADIANCE X ST652 Fig. 26 Determine the vertical pipe length. 5. Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the elbow. Drill 3 holes through each joint and fasten with sheet metal screws. 6. Install the elbow using 3 sheet metal screws at each joint. 7. Measure, and cut if needed, the appropriate length of pipe section needed to make the connection through the wall. Include a 2” overlap; i.e. from the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 27) 8. Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall X ST215 Fig. 27 Measure the horizontal length. sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home. 9. Connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 28) 10. For both CFM and DuraVent Systems: Install the vent terminal. (Fig. 29) Apply high temperature sealant one inch from the ends of the inner and outer collars. Guide the inner and outer vent termination collars into the adjacent pipes. Double check that the vent pipes ...

Эта инструкция также подходит к моделям:
Камины - RADVTSG (4.03 mb)
Камины - RADVTVG (4.03 mb)
Камины - RAD- VTBB (4.03 mb)
Камины - RADVTBD (4.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории