Фрагмент инструкции


It will not “snap” at LP (Red) position. (Fig. 66) LOCAL Motor Top Cap Center Plunger Blue - NG Red - LP FP1037b Valve Pilot Hood Pilot Bracket CO105a Fig. 68 Remove pilot hood. Fig. 66 Depress and turn center plunger. 4. Insure manifold pressure remains between 3.2” - 3.5” Index Tab Snap Ring Allen Wrench CO106a w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a Torx #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP. Pilot ST916 5. Replace motor top cap. Pilot Orifice Conversion 1. Locate pilot. (Fig. 67) Fig. 67 Locate pilot. Fig. 69 Remove pilot orifice. Pilot type 2 (Honeywell Pilot) • Loosen pilot hood turning counterclockwise using a 7/16” wrench. (Fig. 70) NOTE: You may use penetrating oil to prevent pilot hood threads from seizing up. Pilot Hood Index Marks Pilot Bracket CO143 Fig. 70 Remove pilot hood. (Your pilot may have a different appearance.) 2. Replace pilot orifice. Pilot Type 1 (SIT Pilot) • Remove pilot hood by lifting up. (Fig. 68) Do not ST350 remove the snap ring to remove the pilot hood. Jefferson NOTE: It is not necessary to remove the pilot tube for conversion. air shutter adj3/20/00 djt • Remove pilot orifice with Allen wrench. (Fig. 69) • Install the conversion orifice. • Reinstall pilot hood. Be sure to align hood with index tab. • Remove pilot orifice with needlenose pliers. (Fig. 71) NOTE: Use a wrench to hold pilot tube in place while removing the orifice. • Install the conversion orifice. • Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket. 20012697 37 Radiance Direct Vent Gas Heater Pilot Orifice CO1044 Fig. 71 Remove pilot orifice. Burner Orifice Conversion 1. Remove three (3) 3/8” nuts on bottom side of burner pan. (Fig. 72) 2. Carefully remove ember bed by tilting the right side up and lifting out toward the right side of the unit. (Fig. 73) Remove Nuts Remove Nut Bottom View Fig. 72 Remove three (3) nuts securing ember bed in place. ST918 Orifice Venturi Bracket Bracket Pem Studs ........................................ ST919 Fig. 73 Tilt ember bed slightly to correctly place on venturi and air shutter. 3. Remove injector orifice from left burner bracket with a 1/2” wrench. Use a back up wrench to prevent damage to the manifold. (Fig. 74) CO145 Fig. 74 Use two wrenches to avoid damage to manifold. 4. Install conversion orifice. (Refer to Table 2) 5. The air shutter is factory set according to Table 3 and should not need adjustment. The air shutter opening may be verified by measuring as shown in ......... Figure 75. ........................... Orifice Orifice Air Shutter Bracket CO142 Fig. 75 The air shutter setting is 1/2” (13 mm) from the orifice bracket to the edge of the air shutter. ........... All Models ............................... 1. Replace burner making sure venturi on bottom of ember bed aligns with orifice and is seated properly on air shutter assembly. (Fig. 73) Make sure burner is slid into place at a slight angle and opposite to how it was removed. When burner is slid into place, the three (3) pem studs should slide down through clearance holes into the bottom of the control panel. 2. Thread and tighten 3/8” nuts back onto pem studs on underneath side of control panel, reversing Step ......... 1 shown in Figure 72. ........................... 3. Reinstall logs as per instructions on Page 26. 4. Place conversion label on valve. Radiance Direct Vent Gas Heater 5. Replace glass and stove front. 6. Restore gas to system and relight appliance according to Lighting Instructions on Page 30. 7. Leak check the system using a gas leak detector solution. 8. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation. Conversion is complete. Table 2. Injector Orifice Size Matrix Conversion to LP Input (BTU/h) Model Kit # Orifice Part # Minimum Maximum RADVT 20012729 1.75 mm 20012946 25,000 36,000 RADVTC 20012900 Conversion to Natural Gas Input (BTU/h) Model Kit # Orifice Part # Minimum Maximum RADVT 20012899 #31 / 0.120” 20006927 25,000 38,000 RADVTC 20012902 Table 3. Air Shutter Adjustment Model Natural Gas Natural Gas High Altitude LP RADVT/RADVC 1/2” Open 1/2” Open 1/2” Open Table 4. High Altitude Orifice [Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)] Input (BTU/h) Model Orifice Part # Minimum Maximum RADVT/RADVTC (Natural gas only) #33 / 0.113” 20012554 25,000 36,000 *LP models do not need re-orificed up to 4500’ (1,370 m) above sea level. 20012697 39 Radiance Direct Vent Gas Heater Maintenance Your Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts. Lo...

Эта инструкция также подходит к моделям:
Камины - RADVTSG (4.03 mb)
Камины - RADVTVG (4.03 mb)
Камины - RAD- VTBB (4.03 mb)
Камины - RADVTBD (4.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории