Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Vermont Casting, модель RDVOD 3399

Производитель: Vermont Casting
Размер: 1.74 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Check burner orifices for debris, and remove. Turn knob to ON, place rocker switch to ON, millivolt me- ter should read greater than 10 mV. If the reading is okay and the burner does not light, replace the valve. Clean and/or adjust pilot flame for maximum flame im- pingement on thermocouple and thermopile. Check the vent terminal for blockage. Radiance Direct Vent/Natural Vent Gas Heater Instructions for RF Comfort Control Valve The Comfort Control valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 49) 2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner. 3. Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered. 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only. Shut Off Procedure If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan. To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan. Transmitter Operation Off Mode In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off. LOCALREMOTE ON• PILOT OFF• LED Piezo Ignitor Local/Remote Switch Pilotstat Knob LED FP1037 Fig. 49 Comfort control valve. Antenna Motor Top Cap Plug 4. Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2. 5. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately. 6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/ valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control. Display Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdown Timer Low Battery Flame Up Increases Flame Height, Fan Speed Timer, or Set Point Down Decrease Flame, Fan Speed Timer FP1039 or Set Point Mode Auto On Off Countdown Timer Fan Fig. 50 Transmitter diagram. On (Manual) Mode In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons. When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit. Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. Auto Mode In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons. Fan Override During Auto Mode If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon. Change Between F/C Temperature Unit...

Эта инструкция также подходит к моделям:
Электрообогреватели - RDVOD 3354 (1.74 mb)
Электрообогреватели - RDVOD 3360 (1.74 mb)
Электрообогреватели - RDVOD 3369 (1.74 mb)
Электрообогреватели - RDVOD 3390 (1.74 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории