Фрагмент инструкции


The Radiance Direct Vent/Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. The Radiance Direct Vent/Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The Radiance Direct Vent/Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. An accessible tap is located above the pilot/On-Off knob for checking the inlet pressure. ‘Direct Vent’ describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof. Conventional venting systems (Natural Vent) take air from the room for combustion and vent the exhaust vertically through the roof to the atmosphere. This appliance is approved for bedroom installations in the U.S. and Canada. Check local codes for natural vent requirements. This appliance may be installed in an aftermarket* manu 20004188 factured (mobile) home, where not prohibited by state or local codes. WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The Radiance Direct Vent/Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1. Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies. WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance. Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance. The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids. The flow of combustion and ventilation air must not be obstructed.Theinstallationmustincludeadequateaccessibility and clearance for servicing and proper operation. WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Do not burn wood, trash or any other material for which thisappliancewasnotdesigned.Thisapplianceisdesigned to burn either natural gas or propane only. This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 Radiance Direct Vent/Natural Vent Gas Heater Radiance Direct Vent/Natural Vent Stove Dimensions 29......" (7.6cm) 31" (7.9cm) 7" Outer Dia. (1.8cm) ..................... ... 4......" (1.2cm) 14......" (3.7cm) . . . . . . . . 28" (711mm) 5" (127mm) 9......" (241mm) 18......" (464mm) SupplyInlet See Page 6 for Flue Collar Centerline Dimensions. 4188 Fig. 1 Radiance dimensions. Attention The Radiance stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be converted into a Natural Vent unit in the field. If a Natural Vent Heater is desired, the Vermont Castings Z31D00 FSDHAG Draft Hood must be directly installed to the top of the unit according to the installati...

Эта инструкция также подходит к моделям:
Электрообогреватели - RDVOD 3354 (1.74 mb)
Электрообогреватели - RDVOD 3369 (1.74 mb)
Электрообогреватели - RDVOD 3390 (1.74 mb)
Электрообогреватели - RDVOD 3399 (1.74 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории