|
Фрагмент инструкции
33 Roof support and flashing. Venting System Assembly - Natural Vent General Information The Radiance Heater is shipped from the factory as a Direct Vent Heater. It may be converted to a Natural Vent heater by installing the Vermont Castings Model Z31D00 FSDHAG Draft Hood Adapter. The Radiance Heater is approved for installation as a Natural Vent unit. Vermont Castings/Majestic Direct Vent outer pipe (7FSSK) could be used directly after the Draft Hood Adapter up to the ceiling, then B-vent pipe must be used. Do not mix types of B-vent pipe; use components from one maker or the another. Follow the vent component maker’s instructions exactly. (Fig. 34) NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications. Decorative 7” Pipe 4” B-vent Pipe Draft Hood Adapter ST654 Fig. 34 Decorative 7” pipe may be fitted around the B-vent pipe. Vermont Castings/ Majestic outer pipe (7FSSK) may be used after Draft Hood up to the ceiling. MUST Be Kept Clear 20004188 19 2020 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Install Log Set Before beginning log installation, remove stove front and glass frame. Refer to Figures 36 and 37. ST139.. Radiance.. remove front.. 4/20/01 djt ST139 Fig. 36 Remove the stove front. ST141.. pull glass latch.. 10/99 ST141 Fig. 37 Release the latches to remvoe the glass frame. 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAMAGED LOGS. The rear log bracket is shipped packaged with the logs. 2. Install the rear left log by placing it on the sheet metal shelf at the back of the firebox. (Fig. 39) The log should touch the back wall of the firebox. Slide the log to the left until the left side lines up with the left bracket. (Fig. 39) When the log is in place the left front corner of the log should rest on the decorative grate. 3. Install the rear right log by placing it on the sheet metal shelf at the back toward the right. Make sure the right side of the log lines up with the right bracket. (Fig. 39) NOTE: When the right and left rear logs are in place, they should touch the back of the firebox and each other. The Radiance stove, when installed as a Natural vent heater, includes a vent safety switch. (Page 34, Figure 67) Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and possible death. For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z22.1. For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Install the Vent Pipe Apply a bead of sealant around bottom end of inner starter pipe (found in bag with logset) and attach to stove. Apply a bead of sealant around top of inner starter pipe and install the Z31D00 FSDHAG Draft Hood according to Draft Hood instructions. (Fig. 35) Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections. If the layout includes a slip section, this should be the last section of pipe visible in the room, at the ceiling. Complete the venting according to the vent maker’s instructions. ...... ......CEMENT Fig. 35 Install draft hood adpater (FSDHAG). ST655 * Refer to FSDHAG instructions for wiring on Page 34 21 Radiance Direct Vent /Natural Vent Gas Heater 20004188 LG156.. Radiance logs 4/23/01 djt LG156 Fig. 39 Install the left and right rear logs and the right log. Decorative Grate Right Log Right Rear Log Left Rear Log Left Bracket Right Bracket 4. Install the right log by engaging hole on the bottom with pin on the right rear log. (Fig. 40) Set the bottom of the log on the bracket and bring forward to come in contact with decorative grate on right. 5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 41) Use the lava rock to cover brackets on the burner. Do not place lava rocks toward back of burner. The lava rock is shipped inside the bag assembly. Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on page 30. In the U.S.; Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1. Since some municipalities have additional local codes, be sure to consult your local authority. In Canada; consult the local authority ...
Эта инструкция также подходит к моделям:Электрообогреватели - RDVOD 3354 (1.74 mb)
Электрообогреватели - RDVOD 3360 (1.74 mb)
Электрообогреватели - RDVOD 3369 (1.74 mb)
Электрообогреватели - RDVOD 3399 (1.74 mb)