Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Air Health, модель Air+Health AH-RL

Производитель: Air Health
Размер: 1.32 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


NOTE: The view port hole is made of glass and will not allow any UVC rays to pass through. A blue glow should be seen in the duct. 11. If blue glow is not seen, make sure base is properly installed onto duct. There is a proving switch located on the base that needs to be seated properly onto the duct. Make sure that when base is mounted that the plated washer on the switch is raised approximately 3/16. and the switch is fully engaged. (See Figure 6) 12. With standard duct tape or like material, seal all joints and seams of the plenum near the mounting location to reduce any direct viewing of light. MAINTENANCE WARNING: Unplug unit from outlet before commencing inspection and cleaning. NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass. 1. We recommend inspecting and cleaning bulb at least every 6 months depending upon your home environment and condition of conventional filters and duration of use and their replacement cycle. 2. To maintain the bulbs maximum output intensity , replace your Air+Health. Air Purifying System bulb annually, depending upon your home environment using the replacement procedure below. The bulb should operate continuously for maximum bulb life and light effectiveness. REPLACEMENT PROCEDURE WARNING: Unplug unit from wall outlet before starting replacement procedure. NOTE: Wear disposable, non-absorbent protective gloves prior to replacement procedure in case of accidental breakage of glass. 1. Rotate the Air+Health. ballast assembly counter-clockwise until it stops. (See Figure 7) 2. Remove the ballast assembly and bulb from the mounting base. (See Figure 5) 3. Remove the bulb from the bulb socket. (See Figure 4) 4. Install replacement bulb into bulb socket. Do not handle the bulb with bare hands. Oils on the hands tend to reduce bulb intensity. 5. Wipe off the glass with the supplied alcohol wipe. 6. Position the ballast assembly power cord 90° to the view port hole on the mounting base. (See Figure 7) 7. Slide the bulb thought the hole in the mounting base. (See Figure 5) 8. Press the ballast against the mounting base and rotate the ballast assembly clockwise until it stops. (See Figure 8) 9. After assembly is firmly in place, plug the power supply cord into a standard electrical wall outlet. Check bulb operation by looking through the view port hole. A blue glow should be seen in the duct. Figure 7 Figure 8 Figure 5 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the Air+Health. Air Purifying System out of the plenum. Avoid touching the glass portion of the bulb with your hands. Figure 6 Page 5 10. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation. NOTE: If blue light leaks through any portion of plenum and/or around mounting plate, unplug power supply cord immediately and seal affected areas and/or rotate ballast and repeat step #8 above. 11. UV bulbs contain a small amount of mercury, like a typical fluorescent bulb. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA.s Universal Waste Rule, these types of bulbs may be disposed of into household waste. WARNING: Never touch broken bulb or internal contents of bulb. The bulb contains mercury. NOTE: In case of accidental exposure to internal contents of bulb, wash hands and any other affected skin area with mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical attention immediately. TROUBLESHOOTING GUIDE 1. Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety switch is fully engaged 2. If bulb does not light up, rotate ballast slightly clockwise or counter-clockwise 3. If bulb does not light up after rotating ballast, replace bulb. 4. If unit still does not light up after replacing bulb, replace ballast. REPLACEMENT PARTS LIST For replacement parts, contact Home Health Products at: !Phone: 1-866-765-1587 . !Fax: 1-866-253-1029 $Email: sales@homehealthproducts.com CLEAN-UP OF BROKEN BULBS (see warnings on page two of this manual) UV bulbs contain a small amount of mercury, like a typical fluorescent bulb. DO NOT touch any of the mercury with your bare hands. 1. While wearing disposable, non-absorbent protective gloves, pick up the large pieces of glass with your hands. 2. Then, vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all bulb material. 3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag. 4. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA.s Universal Waste Rule, these types of bulbs may be disposed of into household...

Эта инструкция также подходит к моделям:
Воздухоочистители - Air+Health AH-1 (1.32 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории