Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Air Health, модель Air+Health AH-1

Производитель: Air Health
Размер: 1.32 mb
Название файла: 095a9401-2a94-4141-89f2-a63b45c6eec0.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION ITEMS INCLUDED IN KIT: 1-Air+Health. Power Unit 1-Mounting Base 1-Ultraviolet Bulb 4-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Fiberglass Duct Board Mounting Bracket 1-1-1/2. Hole Saw 1-Pair of Safety Glasses (retain for future use when maintaining this product) English...................... Page 1 Francais.................... Page 6 Espanol................Pagina 10 The Air+Health. unit is designed to emit powerful ultraviolet light rays which sterilize and reduce airborne microorganisms as they pass through a home.s heating or air conditioning system. It is installed in the main supply or return duct of the home.s system and operates continuously to automatically purify the air in the home 24 hours a day. PRODUCT QUESTIONS. CALL Home Health Products !Phone: (866)765-1587 " FaxBack: (866)253-1029 $E-mail: sales@airhealth.com for answers on product maintenance, operation or replacement part questions. Page 2 SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the Air+Health. Air Purifying System out of the plenum. • Designed for a closed duct system. Do not mount near a supply or a return air opening. • All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent sealing methods. • Wear supplied safety glasses during installation. They will help block accidental UV exposure to eyes. WARNING: UV light will break down plastic materials not rated for UV exposure: (Examples: wire insulation, flex duct, drain pans and humidifiers) • The unit must be mounted at least 30. from the above stated type of materials. • If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal. WARNING: DO NOT mount this unit outdoors. • This product is designed for indoor installation only (i.e. Attics, crawl spaces, basements, etc.). WARNING: Never touch broken bulb or internal contents of bulb. The bulb contains mercury. • After opening the carton, unpack and inspect the unit and bulb for damage. Do not install this unit if any damage is noticeable. If bulb is damaged, cracked or broken, do not touch bulb or other contents in carton. Close carton and return to seller immediately. • In case of accidental exposure to internal contents of bulb, wash hands and any other affected skin area with mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical attention immediately. NOTE: If you touch the glass of the bulb, you should wipe the glass clean with isopropyl alcohol and a lint free wipe. If the bulb is not cleaned, the film of hand oils causes a reduction in the light intensity. WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source. WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier. WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed to be mounted outside on gas fired or heat pump packaged units**. *Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. **Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building GENERAL INFORMATION The Air+Health. unit uses technology that is recommended by doctors who state that .ultraviolet radiation, properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means of air disinfection..1 Page 3 Square Footage Air+Health. (For ducts at least 16. wide) Volts Watts Amps Hz Up to 2000 1 120 30 .5 60 4000 2 120 30 .5 60 Notes: • For homes with multiple systems, we recommend one unit per system. • For homes with larger applications, multiple units are recommended. Contact technical support at 1-866-765-1587 for sizing. Figure 4 SIZING AND SELECTING UNITS See chart below for determining your homes needs. INSTALLATION 1. Locate a suitable location for the unit downstream from the .A. coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum .cleaning. effect on the .A. coil, mount the unit in the supply plenum as close as possible to the .A. coil. (See Figure 1) CAUTION: Investigate and determine the location of the A coil prior to drilling holes in duct for mounting unit. NOTE: For duct board installation, refer to enclosed ba...

Эта инструкция также подходит к моделям:
Воздухоочистители - Air+Health AH-RL (1.32 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории