Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации GE, модель 625.34855

Производитель: GE
Размер: 1.36 mb
Название файла: b25138f2-b8f8-480a-8c08-53aa39771915.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


// placement face place, /_ the valve is not in ser-__,_ vice positio_, 7o the following to assure correct __ff-_( ! cycle orientation, or tim-_ valve Position Valve ing, between the face cam Indicator plate and valve. Use the MANUAL ADVANCE procedures, page 23. With the RECHARGE NOW button, advance through the recharge cycles until the valve stops in service position, and RECHARGE no longer flashes in the timer. NOTE: The valve motor may automatically drive through several valve positions while searching for service. If an error code occurs, unplug the transformer, then plug in again. SECTION 5 SERVICE TECH INFORMATION 5A. TROUBLESHOOTING MANUAL ADVANCE REGENERATION CHECK NOTE: If water system pressure is low, an elevated drain hose may cause back pressure, This check verifies proper operation of the valve stopping brine draw. motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Always 3. Again press ON/OFF-HOLD to move the make the initial checks, and the manual softener into backwash. Look for a fast flow of initiated diagnostics. water from the drain hose. NOTES: The face plate display must show a steady ao An obstructed flow indicates a plugged top time (not flashing). If an Error code shows, first distributor, backwash flow plug, or drain hose. press the #1 SELECT button to enter the diagnostic display. Press ON/OFF-HOLD to move the softener o into fast rinse. Again look for a fast drain flow. Press the ON/OFF-HOLD button and hold in lo Allow the softener to rinse for a few minutes to for 3 seconds. RECHARGE NOW and FILL flush out any brine that may remain in the resin begin to flash as the softener enters the fill tank from the brining cycle test. cycle of regeneration. When FILL is on steady, o remove the brinewell cover and, using a To return the softener to service, press flashlight, observe fill water entering the tank. ON/OFF-HOLD. a. If water does not enter the tank, look for an BRINE VALVE FLOAT 5ETTIN(_ obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe. CYCLE FLOW RATES (GALLONS PER MIN.) _t Float FILL (flow to salt storage tank) 0.3 (1.1 liters) __""-Stop BRINING "_ .19 (.7 liters) BACKWASH (flow to drain) 2.0 (7.6 liters) liters)liters) BRINE RINSE I .12 (,45 FAST RINSE 2.0 (7.6 liters) o After observing fill, press the ON/OFF-HOLD button to move the softener into brining. A slow flow of water to the drain will begin. 1F Verify brine draw from the brine tank by shining a flashlight into the brinewell and FREEBOARD MEASUREMENT observing a noticeable drop in the liquid level. (Distance from top of resin tank to top of NOTE: Be sure a salt bridge is not preventing resin water with salt contact. If the softener does not draw brine • T ao Resin Tank • nozzle and/or venturi dirty or defective. FREEBOARD • nozzle and venturi not seated properly on 7"-11" gasket. • restricted drain (check drain fitting and 1 hose). Resin Bed • defective nozzle and venturi seal. • other inner valve defect (rotor seal, rotor & disc, wave washer, etc.). SECTION 5 SERVICE TECH. INFORMATION 5B. ROTARY VALVE SERVICE Before working on the valve, turn offthe water supply and disconnect from electrical power. TO RELIEVE PRESSURE: --3 VALVE BYPASS: Close the inlet valve and open a soft water faucet. Then close the outlet valve and open the bypass valve. --SEARS SPECIAL BYPASS: Slide the bypass valve stem to bypass position. Loosen the 3 hex head screws (see A in drawing) toward the back side of the valve to allow pressure water to bleed out Catch water with a rag. DISASSEMBLY To remove a part or group of parts, refer to the valve drawing. A common screwdriver or nut driver, Phillips screwdriver and pliers are the only tools needed to completely disassemble. SERVICING THE VALVE Inspect all o-rings, seals and gaskets for wear or defects. Inspect the bottom surface of the rotor and disc for scratches, chips or wear. NOTE: If replacement is needed, be sure to use the current replacement part. ASSEMBLY Be sure all parts are in place and in the proper position. Lubricate ALL o-rings and seals with FDA approved silicone grease. To install the rotor seal, first place the seal into the valve groove, rounded side down (see cross-section). Apply a light coating of silicone grease to the seal_ crossing ribs. Then, carefully center the wear strip on the seal, and push it downward onto the seal. Install the nozzle and venturi seal and drain seal. Assemble 2 o-rings and the wave washer onto the rotor and disc. Then center the rotor and disc, in the valve body, on the rotor seal. Lower the cover onto the valve body and rotor shaft. Then install the cover holding screws. Before tightening the screws, install the valve cam and gear. Then, turn the rotor (clockwise only) to service position. Tighten the screws using a criss-cross pattern. If a torque wrench is available, torque to 30-40 inch pounds. switch Lubricate the gear on the motor, and the valve cam gear with Moly...

Эта инструкция также подходит к моделям:
Водоочистители - 625.34854 (1.36 mb)
Водоочистители - 625.34854 (1.36 mb)
Водоочистители - 625.34855 (1.36 mb)
Водоочистители - 625.34854 (1.36 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории