|
Фрагмент инструкции
Please read all the instructions in this manual before installing the appliance. Save these instructions for future reference. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance. If the range hood is vented, the air so vented must be ducted into a dedicated duct that is not showed with any other equipment whatsoever. All ducting must conform to all requirements of the local authority. If the range hood is to be used inside he same structure (home or building) as any equipment hat burns combustible material such as oil, coal, gas, etc. then pervision must be made for make up air. Under certain circumstances, the range hood could create a negative air pressure inside the structure. This negative air pressure must not exceed 0.04 mbar (please consult your local HVAC professional for guidance at this point). The use of combustible material in close proximity of the range hood must be avoided. When frying, please pay particular attention to fire risk due to grease. Being highly inflammable, fried oil is especially dangerous. In order to avoid possible fire risk, all instructions for grease- filter cleaning and for removing eventual grease deposits must be followed strictly. If the rating label in the cooker-hood shows the symbol , the appliance is built in class II and it does not need any ground connection. If the rating label in the cooker-hood does not show the symbol ,the appliance is built in class I and it needs the ground connection. Only use this appliance as an exhaust ventilation system for the removal of cooking vapors. DO NOT use to expel flammable substances or any other materials or vapors. The installation procedures in this manual are intended for qualified installers, service technicians or persons with similar qualified background. DO NOT attempt to install this appliance yourself. When performing the electrical connections on the appliance, please ensure that the current supply is provide with ground connection and that the voltage values correspond to those indicated on the label placed inside the appliance itself. Ensure that electrical power is turned off at source before commencing installation. All electrical wiring must be properly installed, insulated and grounded and conform to all applicable codes and standards. Make sure all existing ductwork is clean of grease build up, or ductwork should be replaced, if necessary, to avoid the possibility of a grease fire. Check all joints on ductwork to ensure proper connection and all joints should be properly taped. Be careful when cutting through ceilings or walls not to damage any hidden pipes or electrical wiring. Ensure your kitchen has sufficient air return vents to replace the exhausted air. TABLE OF CONTENTS BEFORE YOU BEGIN 1 DUCTING 1 External Venting Requirements 1 Duct Run Calculation 1 ELECTRICAL 2 Electrical Supply 2 INSTALLATION 3 Positioning the Range Hood 3 Marking the Fixing Holes for the Range Hood 3 Fixing the Main Support Bracket 3 Chimney Installation 4 Hanging the Range Hood 4 Connecting Electricity and Ducting 5 Connecting Chimneys 5 Connecting the Screen (SU 202 only) 5 Re-Circulating Requirements 6 OPERATING PROCEDURES 6 General Advice 6 Functions 7 MAINTENANCE 7 Cleaning the Filter 7 Cleaning the Hood 8 Light Bulb Replacement 8 Battery Replacement 8 WARRANTY 9 BEFORE YOU BEGIN BEFORE YOU BEGIN The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable operation of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance and/or installation. BEFORE YOU BEGIN: It is advisable to test run the range hood before installation. Please read this entire manual and ensure that you are fully conversant with the requirements and limitations D U C T I N G (Not applicable if the range hood is used in re-circulating mode) WARNING: Do not vent this appliance into any other ductwork, spaces between walls, ceilings, attics, garages or any other confined space. External Venting Requirements When planning new ductwork, always look for the most direct route to the outside. Venting can be done through the roof or directly through the back Figure 1 outside wall. (See Figure 1) Only use rigid type metal ducting (plastic ducting is generally not permitted by code). Flexible ducting could restrict airflow by up to 50%. Always fasten connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape. Do not use screws to fasten ductwork to the hood, only use tape as the screws will stop the dampers from opening and your hood will not work. This hood requires a 6” round duct outlet. You can increase the duct size of the duct run but never decrease it. Use the shortest and most direct route ...
Эта инструкция также подходит к моделям:Вентиляторы - SU 207 (264.72 kb)