Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации England's Stove Works, модель 60-SHUNG

Производитель: England's Stove Works
Размер: 136.53 kb
Название файла:
Язык инструкции:
Перейти к скачиванию



Фрагмент инструкции


*Note: Parts orders ONLY: call (800) 516-3636. Technical problems: call (800) 245-6489. TROUBLE SHOOTING GUIDE ITEMS IN THIS GUIDE MARKED WITH AN ASTERISK (*) SHOULD ONLY BE PERFORMED BY A LICENSED GAS FITTER OR EQUIVALENT. WARNING CAUTION Turn off and let the unit cool before servicing. Never use a wire, needle, or similar Only a qualified service person should object to clean the ODS pilot. service or repair this unit. This can damage the pilot. PROBLEM When ignitor is pressed there is no ODS pilot. Flame seems to blow out or will not light. Appliance produces odors. Gas odor even when control knob is in “OFF” position. Smoke or odor during initial burn. Strong gas smell. Gas smell – sooting. When ignitor button is pressed, there is spark at ODS and no ignition. POSSIBLE CAUSE Ignitor electrode positioned wrong. > Ignitor electrode broken. > Ignitor electrode not connected to ignitor cable. > Ignitor cable pinched or wet. > Air in the gas line.> Stove burning vapors from paint, hair spray, glue, etc.> Gas leak. See warning label on cover.> Gas leak. See warning label on cover.> Control valve defective.> Vapors from paint or production process.> LP fuel may have additives or be poor quality.> Excess gas pressure.> Logs may be out of place.> Orifice size may be incorrect.> Gas supply turned off or manual shutoff valve is closed.> Control knob not in “PILOT” position.> Air in gas line when installed.> “ODS” pilot is clogged.> Gas regulator setting is incorrect.> SOLUTION *Replace ignitor electrode. *Replace ignitor electrode. *Replace ignitor cable. *Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry. Replace cable if spark still isn’t there after freeing the pinched wire. Purge air from line (Check to ensure gas is going to pilot.) Ventilate room. Stop using products while operating unit. *Locate and correct all leaks. *Locate and correct all leaks. *Replace control valve. Unit curing out. Will stop. *Shut off gas. Check supplier. *Call utility company/installer. Compare placement of logs to the diagram in the manual. Replace if incorrect. Turn on gas or open supply. Correct knob position. Purge air from system by holding down control knob. Repeat ignition. *Replace “ODS” assembly. *Replace gas regulator. PROBLEM Pilot will not stay lit. “ODS” pilot lights, but flame dies when control knob is released. Pilot flame not touching thermopile, which causes it to cool and shut off the pilot flame. Flame too low. Burner will not come on or has low flame (pilot is okay). Burner will not come on or has an extremely low flame (pilot okay). Delayed ignition of burner. Burner backfiring during ignitio...

Эта инструкция также подходит к моделям:
Вентиляторы - 60-TRULP (136.53 kb)
Вентиляторы - 26-GUHLP (136.53 kb)
Вентиляторы - 26-GUHNG (136.53 kb)
Вентиляторы - 26-GULP (136.53 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории