TO TURN GAS OFF TO APPLIANCE 1) Set thermostat to the lowest setting. 2) Turn off all electric power to the appliance if service is to be performed. 3) Remove control access panel. 4) Turn knob “A” clockwise > until it stops. 3) 4) Set thermostat to desired setting. To turn off the gas to the main burner only, turn gas control clockwise > to pilot. 5) 6) Press down slightly and continue turning clockwise > from pilot position to “OFF”. Replace control access panel. MAINTENANCE INSTRUCTIONS 1) Periodic visual checks of the pilot should be conducted to ensure the flame is present except when the valve control knob is in the “OFF” position. 2) The pilot flame should always be present when the heater is in operation, and should just touch the top of the thermocouple tip. Flame Appearance 6) All components (see parts list) are available directly through the factory. Write or telephone: England’s Stove Works, Inc. Technical Support P.O. Box 206 3) If the pilot flame does not touch the Monroe, VA 24574 thermocouple, then the main burner is (Parts Orders: 800-516-3636) unlikely to function properly. (FAX: 434-929-4810) 7) Installation and all repairs should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. It is imperative that 4) Remove the logs from the grate assembly and vacuum any loose particles from the grate and burner area each month. 5) Flame Appearance In normal operation at the full rate, after 15 minutes the flame appearance should be observed (See diagram). control compartments, burners and circulating air passageways of the appliance be kept clean. Note: More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. WARNING: DO NOT ADJUST THE GAS ORIFICE. KEEP AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. WARNING: FAILURE TO KEEP THE PRIMARY AIR OPENING(S) OF THE BURNER CLEAN MAY RESULT IN SOOTING AND PROPERTY DAMAGE. PARTS LIST Model 26-GUNG/26-GULP and 26-GUHNG/26-GUHLP Model 60-SHUNG/60-SHULP and 60-SHUHNG/60-SHUHLP Model 60-TRUNG/60-TRULP and 60-TRUHNG/60-TRUHLP Exploded View No. Part No.* Part Name* 1 GUV-3211 Screen 2 GUV-3033 Valve Door Cover 3 GUV-3053 Burner Tube Supply Line NOTE: The following Valve/Burner assemblies are for GU, SHU and TRU models 4 GUV-30LP Gas Valve & Burner Assembly – LP GUV-30NG Gas Valve & Burner Assembly – Natural NOTE: The following Valve/Burner assemblies are for GUH, SHUH and TRUH (Hearth-adaptable models) 5 GUV-30HLP GUV-30HNG GUV-12741 Gas Valve & Burner Assembly – LP Gas Valve & Burner Assembly – Natural Pilot and Bracket – LP GUV-50741 Pilot and Bracket – Natural 6 GUV-3012 Valve Bracket 7 8 9 GUV-31612 GUV-3166 GU-3053 GUV-100Pilot Supply Line – LP Pilot Supply Line – Natural Main Gas Supply Line Burner Tube 10 11 12 13 GU-38 GU-3812 GU-3814 GU-LP051 3/8” Brass Fitting 3/8” x .” Fitting 3/8...

Эта инструкция также подходит к моделям:
Вентиляторы - 60-TRULP (136.53 kb)
Вентиляторы - 26-GUHLP (136.53 kb)
Вентиляторы - 26-GUHNG (136.53 kb)
Вентиляторы - 26-GULP (136.53 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории