Фрагмент инструкции




Table 1 Battery LED status (continued)
Before you begin
Item Description
Status
Green slow flash—Discharging, cache
CAUTION:
When handling system
module being powered by battery; action
required
components, there is a danger to equipment
from electrostatic discharge (ESD). Use proper
Amber flashing—Fault condition
anti-static protection at all times:
2
Controller
Green—System activity

LED
Keep the replacement component in the
Blinking amber—Fault condition
ESD bag until needed.
Off—No system activity

Wear an ESD wrist strap grounded to an
unpainted surface of the chassis.

If an ESD wrist strap is unavailable, touch
Removing the failed component
an unpainted surface of the chassis before
handling the component.
Remove the failed battery by squeezing the release

tabs (1) and pulling the battery straight out (2).
Never touch connector pins.
CAUTION:
Check the expiration date of the
IMPORTANT:
As you remove the battery from
battery spare part kit, located on the label. If
the controller, keep it level until it is completely
the battery in the spare part kit is discharged,
disengaged. If the battery is tilted, it is possible
the system may not recharge it. Contact HP
to damage the battery or controller.
support before proceeding.
Verifying component failure
IMPORTANT:
See the storage system
administration guide for additional information.
Check the controller and battery LEDs.
Installing the replacement component
Insert the new battery, making sure that it seats
properly by clicking and locking into place.
IMPORTANT:
As you insert the battery in the
controller, keep it level until it is completely
installed. If the battery is tilted, it is possible to
damage the battery or controller.
Table 1 Battery LED status
Item Description
Status
1
Battery LED
Green solid—Healthy condition; battery fully
charged
Green rapid flash—Being recognized by
controller; flashes rapidly when battery first
installed and until recognized by controller
Page 2


...

Эта инструкция также подходит к моделям:
Устройства обработки данных - HP IBRIX X9320 10GbE Performance Block (203.05 kb)
Устройства обработки данных - HP IBRIX X9320 IB Performance Block (203.05 kb)
Устройства обработки данных - HP StoreAll 8800 Storage Node (203.05 kb)
Устройства обработки данных - HP StoreAll 9320 1GbE Storage Node Pair (203.05 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории