Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель HP IBRIX X9320 1GbE Performance Block

Производитель: HP
Размер: 343.64 kb
Название файла:
Язык инструкции:enal
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Segment evacuation. The following restrictions apply when removing storage from the cluster:

You cannot evacuate or remove the root segment (segment #1).

The file system must be quiescent (no active I/O while a segment is being evacuated). Previous
versions of the administrator guide incorrectly stated that the file system can be active.
Managing CIFS shares with the Microsoft Management Console (MMC). To manage CIFS shares, open
an MMC with the Shared Folders snap-in. (Instructions for creating and saving an MMC with the
snap-in begin on page 62 of the HP X9000 File Serving Software File System User Guide.) The user
guide incorrectly states, on page 64, that you can access the MMC from the Start menu by selecting
Computer, right-clicking, and selecting Manage.
Creating FTP shares. The HP X9000 File Serving Software File System User Guide states on page 80
that you can create multiple shares having the same physical path, but with different sets of properties,
and then assign users to the appropriate share. The documentation should also note that you need to
use a different IP address or port number for each share.
Creating directories for HTTP. If a user uploads a file to an HTTP share and specifies a subdirectory
that does not already exist, the subdirectory will be created. For example, you could have a share
mapped to the directory /ifs/http/ and using the URL http_url. A user could upload a file into
the share:
curl -T file http://:/http_url/new_dir/file
If the directory new_dir does not exist under http_url, the http service automatically creates the
directory /ifs/http/new_dir/ and sets the permissions to 777. If the anonymous user performed
the upload, the new_dir directory is owned by daemon:daemon. If a non-anonymous user performed
the upload, the new_dir directory is owned by user:group.
Creating directories for FTP. If a user uploads a file to an FTP share and specifies a subdirectory that
does not already exist, the subdirectory will not be created automatically. Instead, the user must
explicitly use the mkdir ftp command to create the subdirectory. The permissions on the new directory
are set to 777. If the anonymous user created the directory, it is owned by ftp:ftp. If a
non-anonymous user created the directory, the directory is owned by user:group.
User access for HTTP and FTP shares. The administrator must ensure that all users who are given read
or write access to HTTP or FTP shares have sufficient access permissions at the file system level for the
directories exposed as shares.
Accessing FTP shares. The HP X9000 File Serving Software File System User Guide incorrectly states
on page 83 that when a file is uploaded into an FTP share, the file is owned by ftp:ftp and not by
the user who uploaded to the share. In 5.5.257 and later releases, files uploaded to an FTP share are
owned by the user doing the upload.
Accessing HTTP shares. The HP X9000 File Serving Software User Guide incorrectly states on page
92 that when a file is uploaded into an HTTP share, the file is owned by daemon:daemon and not
by the user who uploaded to the share. In 5.5.257 and later releases, files uploaded to an HTTP share
are owned by the user doing the upload.
Flex-10 networks on X9720 systems. The HP X9720 Network Storage System Administrator Guide
states on page 182 that the X9720 system uses balance-ALB mode for bond1. This is incorrect. The
X9720 system uses mode 1 (active/backup) for network bonds.
Installing a minor kernel update on Linux clients
The X9000 client software is upgraded automatically when you install a compatible Linux minor kernel
update. If you are planning to install a minor kernel update, first run the following command to verify
that the update is compatible with the X9000 client software:
/usr/local/ibrix/bin/verify_client_update
The following example is for a RHEL 4.8 client with kernel version 2.6.9-89.ELsmp:
# /usr/local/ibrix/bin/verify_client_update 2.6.9-89.35.1.ELsmp
nl
16
Fixes


...

Эта инструкция также подходит к моделям:
Устройства обработки данных - HP IBRIX X9320 10GbE Performance Block (343.64 kb)
Устройства обработки данных - HP IBRIX X9320 IB Performance Block (343.64 kb)
Устройства обработки данных - HP StoreAll 8800 Storage Node (343.64 kb)
Устройства обработки данных - HP StoreAll 9320 1GbE Storage Node Pair (343.64 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории