• Analyze any failure messages received. HP fault monitoring software
2.
Slide the power supply into the enclosure until a click is detected
provides a recommended action.
when fully seated.
• For the EVA only: Check the status using HP Command View EVA:
1.
In the Navigation pane, select Storage system > Hardware >
Disk Enclosure.
2.
In the Disk Enclosure Properties pane, select the Power tab.
3.
The Operational State of power supply 1 or 2 should be
Failed.
4.
To help identify the correct enclosure, click the General tab, and
then select Locate > Locate ON to illuminate the enclosure blue
UID indicator.
• MSA6X/7X only: Check the power supply bi-color LED.
• Green = Power turned on and power supply functioning normally.
• Amber = Standby (auxiliary power present)
• Blinking amber = Power to this power supply not present
15801
• Off = One or more of the following conditions exist: AC power
unavailable, power supply failed, or power supply exceeded
Figure 3 Installing a power supply
current limit
3.
Connect the AC power cord to the power supply.
• EVA only: Check the power supply bi-color LED.
• Green = Flashing when powering up. Solid during normal oper-
ation.
Verifying proper operation
• Amber = Solid indicates a fault condition, and that the power
supply may need to be replaced.
After replacing the power supply, check the following to verify the
component is operating properly:
Removing a power supply
NOTE:
1.
Disconnect the AC power cord from the power supply to be
Wait one minute for the system to check the component status.
replaced.
2.
Move the mounting latch to the left (1, Figure 2), grasp the handle,
and pull the power supply out a short distance.
• The green LED should become lit as soon as the power cord is
plugged in.
3.
Position one hand under the power supply, and with the other hand,
• EVA only: From HP Command View EVA, navigate to the component
pull the power supply out of the enclosure (2).
as described in Verifying component failure and check the status. It
should be Good.
1
2
15800
Figure 2 Removing a power supply
Installing a power supply
1.
Remove any connector cover that may be protecting the AC power
connector on the new power supply.
Page 2


...

Эта инструкция также подходит к моделям:
Устройства обработки данных - HP 4400 Dual Controller Enterprise Virtual Array (350.76 kb)
Устройства обработки данных - HP EVA6400 Array (350.76 kb)
Устройства обработки данных - HP EVA6400 for Storage Centric Rack (350.76 kb)
Устройства обработки данных - HP EVA8400 Array (350.76 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории