Войти:
Скачали: 18   Размер: 282 kb   Производитель: Bryant  
Категория: Термостаты
@name

SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Residential Light Commercial Systems Carrier Corporation 4/01 TSTATBBPS101 Page 1 Front Panel Front Panel 67 70 HEAT COOL AUTO o oAm 6:0368 Su Backlit LCD Display Warmer or + Button Cooler or - Button Mode Button Heat or Cool Indicator Red = Heat, Green = Cool 67 70 HEAT COOL AUTO o oAm 6:0368 S SET CLOCKPROGRAMVACATION OUTSIDEFAN MODE Programmable Thermostat FAN OUTSIDE VACATION PROGRAM SET CLOCK Pag

Скачали: 11   Размер: 258 kb   Производитель: Bryant  
Категория: Термостаты
@name

Off Hp 3 OFF Setup Press MODE Continued Page 12 Advanced Setup Advanced Setup B Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) O 0 4Setup Press Eh 5 OFF Setup MODE Select Electric Heat On or Off. (Step 5 only appears if heat pump is off in step 3) Press 2 6Setup 88 MODE Adjust the deadband from 1 - 6 degrees. Press 2 7 COOL HEAT Setup MODE Adjust the minimum difference between cooling & heating setpoints. (0 - 6 ) Press MODE Continue

Скачали: 5   Размер: 432 kb   Производитель: Bryant  
Категория: Термостаты
@name

This is done in Advance Setup Step #5, by selecting 1. The room temperature may be viewed by holding in the On/Off button for 2 seconds. Releasing the On/Off button will return the display to the previous screen. OUTDOOR SENSOR An outdoor temperature sensor may be connected to this thermostat. Totaline offers wired or wireless models. Compatible models include: P474-0401RF/REC & P474-0400. Consult the remote sensor instruction sheet for wiring connections. Page 15 About Advanced Features & Opera

Скачали: 1   Размер: 522 kb   Производитель: Bryant  
Категория: Термостаты
@name

DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING WARNING THE NEW THERMOSTAT. CAUTION The 2 Alkaline “AA” batteries must be replaced at least every 12 months to assure proper operation. The thermostat will display the Low Battery code (fig. 1) on the display of the thermostat when it is time to replace the batteries. FIG. 1 When is displayed the batteries must be replaced immediately. The manufacturer cannot be liable for improper operation of the

Скачали: 2   Размер: 176 kb   Производитель: Bryant  
Категория: Термостаты
@name

Residential Light Commercial Systems Carrier Corporation 04/01 TSTATBBNB001 Page 1 Front Panel Front Panel AUTO COOL 74 HEAT 72 72 5 1 2 3 4 1 2 3 4 5 Liquid Crystal Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Heat = Red, Cool = Green Page 2 Display Display 1 Mode IndicatorsFan On AUTO OFF COOL 88 HEAT 88882 3 1 1 3 1 1 4 3 2 4 Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO -

Скачали: 3   Размер: 64 kb   Производитель: Bryant  
Категория: Термостаты
@name

When disabled, AUTO icon does not appear when successive presses of MODE button are used to move between OFF, HEAT, and EHEAT (in heat pump systems). Factory default is ON (AUTO mode enabled). TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 15. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 15 setting. 4. Use up and down buttons to move between available Option 15 choices o

Скачали: 1   Размер: 64 kb   Производитель: Bryant  
Категория: Термостаты
@name

TO ADJUST: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 01. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 01 setting. 4. Use up and down buttons to move between the available Option 01 values of 1 to 9. Factory default is 3. 5. Press MODE button again to return to Option 01. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to e

Скачали: 7   Размер: 125 kb   Производитель: Bryant  
Категория: Термостаты
@name

11—Two-Speed Heat Pump ® Fig. 12—Two-Speed Heat Pump with Single-Stage Furnace with 2-Stage or Variable-Speed Furnace —Model 2S Thermostat —Model 2S Thermostat —9— MODEL 2S SINGLE-SPEED THERMOSTAT EASY SELECT HEAT PUMP TERMINAL BOARD MODEL 2S TYPICAL TWO-SPEED THERMOSTAT FAN COIL HEAT PUMP 24 VAC HOT FAN HEAT STAGE 3 COOL/HEATSTAGE 2 RVS COOLING COOL/HEATSTAGE 1 R G W/W1 Y/Y2 O/W2 Y1/W2 R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C W2 R O Y1 W3 See notes 3, 7, 8, 9, and 11 W2 Y

Скачали: 2   Размер: 53 kb   Производитель: Bryant  
Категория: Термостаты
@name

HEAT AUTOFAN AUX. HEAT * Air Conditioner Model * Heat Pump Model (HH07AT212) (HH07AT214) NON-PROGRAMMABLE THERMOSTAT ® * Standard Model (AC, HP, 2S) PROGRAMMABLE THERMOSTAT AND THERMIDISTATTM CONTROL ® * Standard Model (AC, HP, 2S) * Dual Fuel Model (DF) * ThermidistatTM Control Model (RH) The Bryant electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump, and 2-speed models; a programmable dual fuel model, and a programmable ThermidistatTM Con

Скачали: 0   Размер: 65 kb   Производитель: Bryant  
Категория: Термостаты
@name

IX. LIGHT SENSOR ADJUSTMENT The light sensor is used for light-activated operation. The sensor can be adjusted for a variable degree of sensitivity. The sensitivity adjustment screw is located on the inner cover of the thermostat, near the DOWN ARROW button. Turning the screw clockwise increases the sensitivity of the sensor to light. Turning the screw counterclockwise decreases the sensitivity of the sensor to light. To check for correct sensitivity, place the thermostat in Program On mode. The