Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации ADTRAN, модель ERS-100 (5K02-51)

Производитель: ADTRAN
Размер: 3.8 mb
Название файла:
Язык инструкции:
Перейти к скачиванию



Фрагмент инструкции


Installing the Server into a Telco Rack If you are installing the 8e6 server unit into a Telco type rack, follow the directions given on the previous page for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the Telco rack. Check the Power Supply This server is equipped with a universal power supply that handles 100-240 V, 50/60 Hz. A standard power cord interface (IEC 950) facilitates power plugs that are suitable for most European, North American, and Pacific Rim countries. Power Supply Precautions Warning: Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep the server operating in case of a power failure. In geographic regions that are susceptible to electrical storms, 8e6 highly recommends plugging the AC power cord for the server into a surge suppressor. Use appropriately rated extension cords or power strips only. Allow power supply units to cool before touching them. General Safety Information Server Operation and Maintenance Precautions Warning: Observe the following safety precautions during server operation and maintenance: WARNING: If the server is used in a manner not specified by the manufacturer, the protection provided by the server may be impaired. WARNING: 8e6 Technologies is not responsible for regulatory compliance of any server that has been modified. Altering the server’s enclosure in any way other than the installation operations specified in this document may invalidate the server’s safety certifications. CAUTION: Never pile books, papers, or other objects on the chassis, drop it, or subject it to pressure in any other way. The internal circuits can be damaged, and the battery may be crushed or punctured. Besides irreparable damage to the unit, the result could be dangerous heat and even fire. CAUTION: There are no user-serviceable components inside the chassis. The chassis should only be opened by qualified service personnel. Never disassemble, tamper with, or attempt to repair the server. Doing so may cause smoke, fire, electrical shock, serious physical injury, or death. Do not insert objects through openings in the chassis. Doing so could result in a short circuit that might cause a fire or an electrical shock. Do not operate the server in an explosive atmosphere, in the presence of flammable gases. To ensure proper cooling, always operate the server with its covers in place. Do not block any openings on the chassis. Do not place the server near a heater. Always exit the software application properly before turning off the server to ensure data integrity. Do not expose the server to rain or use near water. If liquids of any kind should leak into the chassis, power down the server, unplug it, and contact 8e6 Technologies technical support. Disconn...

Эта инструкция также подходит к моделям:
Сетевое оборудование - ER3-200 (5K02-56) (3.8 mb)
Сетевое оборудование - ER3-100 (5K02-55) (3.8 mb)
Сетевое оборудование - ER3-100 (5K02-55) (3.8 mb)
Сетевое оборудование - ER3-200 (5K02-56) (3.8 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории